35 Ill. Adm. Code 845.600
Groundwater Protection Standards
Section 845.600 Groundwater Protection Standards
a) For existing CCR surface impoundments and for
inactive CCR surface impoundments:
1) The groundwater
protection standards at the waste boundary must be:
A) Antimony: 0.006 mg/L
B) Arsenic: 0.010 mg/L
C) Barium: 2.0 mg/L
D) Beryllium: 0.004 mg/L
E) Boron:
2 mg/L
F) Cadmium: 0.005 mg/L
G) Chloride: 200 mg/L
H) Chromium: 0.1 mg/L
I) Cobalt:
0.006 mg/L
J) Fluoride:
4.0 mg/L
K) Lead:
0.0075 mg/L
L) Lithium:
0.04 mg/L
M) Mercury: 0.002 mg/L
N) Molybdenum:
0.1 mg/L
O) pH: 6.5-9.0 units
P) Selenium:
0.05 mg/L
Q) Sulfate: 400 mg/L
R) Thallium: 0.002 mg/L
S) Total Dissolved Solids:
1200 mg/L
T) Radium
226 and 228 combined: 5 pCi/L
2) For
constituents with a background concentration higher than the levels identified in
subsection (a)(1), the background concentration must be the groundwater
protection standard.
b) For
new CCR surface impoundments, the groundwater protection standards at the waste
boundary must be background for the constituents listed in subsection (a)(1)
, calcium, and turbidity.
c) The
owner or operator of a CCR surface impoundment may not obtain alternative
groundwater quality standards in 35 Ill. Adm. Code 620.450(a)(4) for the
constituents in subsections (a) and (b) before the end of post-closure care
under Section 845.780, when closing with a final cover system, or before the
end of groundwater monitoring under Section 845.740(b), when closing by
removal.