35 Ill. Adm. Code 848.202
Requirements
Section 848
Section 848.202 Requirements
a) Owners and operators of any site at which more than 50 used or
waste tires are located at any one time must comply with the following
requirements:
1) No used or waste tires shall be placed
or accumulated outside of a building or fully enclosed container, unless the
used or waste tires are placed on or accumulated in a storage pile that is
separated from:
A) all other storage piles by a firebreak
that is not less than 40 feet wide;
B) all buildings, whether on or off site, by
a firebreak that is not less than 50 feet wide;
C) all of the site's property boundaries by
a firebreak that is not less than 50 feet wide;
D) all outdoor activities at the site that
present a risk of fire by a firebreak that is not less than 250 feet wide;
E) all trees by a firebreak that is not less
than 100 feet wide;
F) all grass, weeds, brush, and combustible
ground vegetation by a firebreak that is not less than 40 feet wide; and
G) any combustible material not listed in this
subsection (a)(1) by a firebreak that is not less than 40 feet wide.
2) No used or waste tires shall be placed
or accumulated outside of a building or fully enclosed container, unless they
are placed on or accumulated in a storage pile that:
A) is no more than 10 feet high by 50 feet
wide by 100 feet long; and
B) has no side slope angle that exceeds 60
degrees from horizontal.
3) No used or waste tires shall be placed
or accumulated on site unless they are drained of water and prevented from
accumulating water thereafter.
4) If more than 20 used or waste tires are
accepted at the site from a vehicle that fails to display the placard required
under Subpart F, the owner or operator of the site must collect the following
information and forward it to the Agency within 5 business days after accepting
the tires:
A) the name, address, and driver's license
number of the person driving the vehicle;
B) the license plate number and vehicle
identification number (VIN) of the vehicle; and
C) any available information about the
sources of the tires being accepted.
5) No used or waste tires shall be placed
or accumulated on site in any area where the grade of the ground surface
exceeds two percent slope, unless the used or waste tires are stored within a
berm or other structure that satisfies the requirements of subsection (c)(1)(C).
6) All activities at the site that present
a risk of fire must be conducted either:
A) within a building and in accordance with Section 848.204(c)(4);
or
B) outdoors and separated from all used or
waste tires by at least 250 feet.
b) In addition to the requirements set forth in subsection (a), owners
and operators of any site at which more than 60 tons of used or waste tires are
located at any one time must comply with the following requirements.
1) The contingency planning and emergency response requirements
of Section 848.203 must be met.
2) The recordkeeping and reporting requirements of Subpart C must
be met.
3) A tire storage plan that is designed to ensure compliance with
the requirements of this Section must be developed for the site and must be
adhered to at all times. A copy of the plan must be maintained on site and must
be made available at the site for inspection and photocopying by the Agency
during normal business hours.
c) In addition to the requirements set forth in subsections (a)
and (b), owners and operators of any site at which more than 125 tons of used
or waste tires are located at any one time must comply with the following
requirements:
1) No used or waste tires shall be placed or accumulated outside
of a building or fully enclosed container, unless:
A) the used or waste tires are stored in an area completely
surrounded by fencing that is:
i) at
least 6 feet high; and
ii) in
good repair;
B) the entrances to the area where the used or waste tires are
located are controlled at all times by an attendant, locked entrances,
television monitors, controlled roadway access or other equivalent mechanisms;
C) the
used or waste tires are completely surrounded by an earthen berm or another
walled, impermeable, aboveground structure that is:
i) not
less than 2 feet in height;
ii) capable
of containing runoff resulting from tire fires; and
iii) crossed
by a stabilized roadway at not fewer than 2 points of access that are
sufficiently separated from one another to provide 2 independent means of
ingress and egress during fire conditions; and
D) one or
more stabilized roadways provide firefighting personnel and equipment access to
all portions of the tire storage area.
2) No used or waste tires shall be placed
or accumulated within 250 feet horizontally of the ground surface directly
beneath any electrical power line that has a voltage in excess of 750 volts or
that supplies power to a fire emergency system.
3) The perimeter of each group of storage
piles at the site must be separated at all times from the perimeter of all
other groups of storage piles at the site by a firebreak of at least 75 feet.
No group of storage piles may be composed of more than 3 individual storage
piles, and no storage pile in such a group may have dimensions greater than
those described in subsection (a)(2).