56 Ill. Adm. Code 6000.270
Inflatable Amusement Attractions
Section 6000
Section 6000.270 Inflatable
Amusement Attractions
All inflatable amusement attractions shall meet the
manufacturer's standards and specifications.
a) Anchorage in accordance with the manufacturer's specifications
shall be provided for inflatable amusement attractions and examined daily.
b) The fabric on inflatable amusement attractions shall be
examined daily for rips and tears and those found shall be repaired
immediately.
c) Ventilators and fans shall be shielded by one of the following
methods:
1) Fencing around unit;
2) Mesh guarding over unit; or
3) Total enclosure.
d) Covered or enclosed inflatable amusement attractions shall be
so designed that if a power failure occurs the structure will remain
substantially erect for more than the time required to evacuate the normal
rated occupancy or 5 minutes, whichever is the longer period.
e) No inflatable amusement attraction shall be placed in service
unless the owner:
1) Complies with the applicable ASTM F2374 standard (ASTM
F2374-17 for attractions manufactured on or after January 1, 2021; ASTM
F2374-10 otherwise); and
2) Complies with ASTM F2374-17, Appendices X2 (Anchoring System
Design) and X7 (Staking Guidelines).
f) No inflatable amusement attraction manufactured after January
1, 2020 shall be placed in service unless the owner:
1) Receives certification that the attraction has been designed,
constructed and tested to the standards established by ASTM F2374-17;
2) Obtains and complies with the manual containing the operation
procedures established by ASTM F2374-17; and
3) Obtains and complies with the maintenance procedures manual established
by ASTM F2374-17.