77 Ill. Adm. Code 295.9000
Physical Plant
Section 295
Section 295.9000Â Physical
Plant
a)Â Â Â Â Â Â Â Â The establishment shall comply with
the residential board
and care occupancies chapter of the National Fire Protection Association's
(NFPA) Life Safety Code
(Life Safety Code)
101,
Chapter 32 for new establishments
and Chapter 33 for existing establishments.
b)Â Â Â Â Â Â Â Â The establishment shall comply with
local and State
building codes for the building type
and local ordinances, fire codes, and
zoning requirements. In the case of a conflict between a local requirement and
this Part, the more stringent requirement shall apply. The establishment may
petition the Department for a determination as to which requirement is
applicable. The Department shall respond within 30 days after receipt of the
petition.
c)Â Â Â Â Â Â Â Â The establishment shall comply with the
accessibility
standards of the Americans with Disabilities Act
(ADA Accessibility
Guidelines). (Section 20(1) of the Act)
d)Â Â Â Â Â Â Â Â If the establishment is subject to the requirements of the
Illinois Accessibility Code, it shall be deemed residential.
e)Â Â Â Â Â Â Â Â The water supply shall comply with all applicable State codes
and local ordinances. Each establishment shall be served by:
1)Â Â Â Â Â Â Â Â Water from a municipal water system; or
2)Â Â Â Â Â Â Â Â A water supply that complies with the Department's Drinking
Water Systems Code; or
3)Â Â Â Â Â Â Â Â A water supply that complies with the Department's Public Area
Sanitary Practice Code.
f)Â Â Â Â Â Â Â Â All sewage and liquid wastes shall be discharged into a public
sewage disposal system or shall be collected, treated, and disposed of in a
private sewage disposal system that is designed, constructed, maintained and
operated in accordance with the Department's Private Sewage Disposal Code.
g)Â Â Â Â Â Â Â Â The Department may grant a waiver of physical plant standards
in accordance with Section 295.1090 (Waivers). Waivers will not be granted for
compliance with the Life Safety Code; however, the Department will recognize
equivalencies. The Department shall review waivers relating to physical plant
standards issued pursuant to this Section at the time of the annual visits and
shall renew waivers, unless:
1)Â Â Â Â Â Â Â Â the condition of the physical plant has deteriorated or its
use substantially changes so that the basis upon which the waiver was issued is
materially different; or
2)Â Â Â Â Â Â Â Â the establishment is renovated or substantially remodeled in
such a way as to permit compliance with the applicable requirements without
substantial increase in cost.
h)Â Â Â Â Â Â Â Â A resident unit shall not be used as access to a common room,
common bathroom, or another bedroom or unit.
i)Â Â Â Â Â Â Â Â Â Each establishment shall provide individual mailboxes or mail
delivery for residents.
j)Â Â Â Â Â Â Â Â Â An assisted living establishment shall have no units below
ground level. A shared housing establishment may have units below ground level
if the units have a window with direct access to the outside.
k)Â Â Â Â Â Â Â Â All plumbing systems shall be designed and installed in
accordance with the requirements of the Illinois Plumbing Code except that the
number of resident-required water closets, lavatories, bathtubs, showers, and
other fixtures shall be as required by this Part.
l)Â Â Â Â Â Â Â Â Â Illumination
Illumination
systems shall be installed and maintained to ensure sufficient general
lighting, lighting for reading, night lighting for corridors and stairwells,
and lighting for emergency and disaster situations. Common areas shall be
lighted to assure the safety of residents. Outdoor areas shall be adequately
illuminated.
m)Â Â Â Â Â Â Â Telephone
A telephone
shall be located in an area easily accessible to residents that allows for
private conversations.
n)Â Â Â Â Â Â Â Â The establishment shall maintain a means of unlocking all
doors, which may be used in emergency situations or as provided in the
establishment contract.
o)Â Â Â Â Â Â Â Â Kitchen
Facilities housing 10 or more
residents shall comply with the requirements of NFPA 96, Ventilation Control
and Fire Protection of Commercial Cooking Operation.