77 Ill. Adm. Code 330.3110
Bedrooms
Section 330
Section 330.3110Â Bedrooms
Every building shall meet the
following requirements:
a)Â Â Â Â Â Â Â Â Resident bedrooms in all facilities shall be a minimum of ten
feet between walls or a wall and any built-in furniture or storage space. Each
such bedroom shall have an entrance directly off a corridor with an entrance
door not less than three feet wide that swings into the room.
b)Â Â Â Â Â Â Â Â Each single bedroom used for a resident shall have at least
100 square feet of usable net floor area, not including any space taken up for
closets, wardrobes, bathrooms, and clearly definable entryway areas.
c)Â Â Â Â Â Â Â Â Each multiple bedroom used for residents shall have at least
80 square feet of usable floor area for each resident, not including any space
taken for closets, wardrobes, bathrooms, and clearly definable entryway areas.Â
Beds shall be at least three feet apart, and no more than three deep from an
outside wall.
d)Â Â Â Â Â Â Â Â Maximum capacity of a bedroom shall be four residents.
e)Â Â Â Â Â Â Â Â Each bedroom shall be at or above grade level.
f)Â Â Â Â Â Â Â Â Each room used as a resident bedroom shall have at least one
outside window, and a total window area to the outside equal to at least
one-tenth the floor area of the room. Windows shall open and close easily.
g)Â Â Â Â Â Â Â Â Each bedroom shall have adequate and satisfactory artificial
light and be equipped with at least three duplex electric convenience outlets.Â
Electric cords shall not be strung from a ceiling fixture. There shall be an
electric switch near the door to control at least one light in the room.
h)Â Â Â Â Â Â Â Â Provide a closet or wardrobe of at least two feet square for
each resident.
i)Â Â Â Â Â Â Â Â Â Bedroom doors shall have no hardware that will allow the
resident to lock himself in the room. The door may be keyed on the corridor
side to prevent others from entering the room.