77 Ill. Adm. Code 390.TABLE C
C Sound Transmissions Limitations
Section 390.TABLE C ย ย Sound
Transmissions Limitations
Airborne
Sound Transmissions Class (STC)
a
Partitions
Floors
Impact
Insulation Class (IIC)
b
Floors
Residents' Room to Residents'
Room
40
to 44
40
to 44
44
Public space to Residents'
Room
c
45
to 49
45
to 49
49
d
Service areas to Residents'
Room
e
50
to 54
50
to 54
49
d
a
Sound transmission class (STC) shall be determined by
tests in accordance with methods set forth in ASTM Standard E 90 and ASTM
Standard E 413.
b
Impact insulation class (IIC) shall be determined in
accordance with criteria set forth in HUD FT/TS-24, "A Guide to Airborne,
Impact and Structure Borne Noise-Control in Multi-Family Dwellings."
c
Public space includes Lobbies, Dining Rooms, Recreation
Rooms, and similar spaces.
d
Impact noise limitation applicable only when Corridor,
Public Space, Service Area, or Play or Recreation Area is over patients' room.
e
Service areas include Kitchens, Elevator Machine Rooms,
Laundries, Garages, Maintenance Rooms, Boiler and Mechanical Equipment Rooms,
and similar spaces of high noise.ย Mechanical equipment located on the same
floor or above Patients' Rooms, Offices, Nurses Stations, and similar occupied
spaces shall be effectively isolated from the floor.