77 Ill. Adm. Code 785.415
Equipment and Utensils
Section 785
Section 785.415Â Equipment
and Utensils
a)Â Â Â Â Â Â Â Â General Construction, Repair, and Installation
1)Â Â Â Â Â Â Â Â The equipment and utensils used for processing milk and
manufacture of dairy products shall be constructed to be easily demountable
where necessary for cleaning and sanitizing. The product contact surfaces of
all utensils and equipment such as holding tanks, pasteurizers, coolers, vats,
agitators, pumps, sanitary piping, and fittings or any specialized equipment
shall be constructed of stainless steel, or other equally corrosion-resistant
material. Nonmetallic parts other than glass having product contact surfaces
shall meet 3-A Sanitary Standards for Plastic or Rubber and Rubberlike
Materials.
2)Â Â Â Â Â Â Â Â All equipment and piping shall be designed and installed so as
to be easily accessible for cleaning, and shall be kept in good repair, free
from cracks and corroded surfaces. New or rearranged equipment shall be set
away from any wall or spaced in such a manner as to facilitate cleaning and to
maintain good housekeeping. All parts or interior surfaces of equipment, pipes
(except certain piping cleaned in place) or fittings, including valves and
connections, shall be accessible for inspection. Milk and dairy product pumps
shall be of a sanitary type and easily dismantled for cleaning or shall be of
approved construction to allow effective cleaning in place in accordance with
3-A Sanitary Standards.
3)Â Â Â Â Â Â Â Â All CIP systems shall comply with the 3-A Sanitary Practices
for permanently Installed Sanitary Product, Pipelines, and Cleaning Systems.
b)Â Â Â Â Â Â Â Â Weigh Cans and Receiving Tanks:Â Weigh cans and receiving
tanks shall meet the 3-A Sanitary Standards and shall be easily accessible for
cleaning both inside and outside and shall be elevated above the floor and
protected sufficiently with covers and baffles to prevent contamination from
splash, condensate, and drippage. When necessary to provide easy access for
cleaning of floors and adjacent wall areas, the receiving tank shall be
equipped with wheels or casters to allow easy removal.
c)Â Â Â Â Â Â Â Â Can Washers:Â Can washers shall have sufficient capacity and
ability to discharge a clean, dry can and cover and shall be kept properly
timed in accordance with the instructions of the manufacturer. The water and
steam lines supplying the washer shall maintain a uniform pressure and be
equipped with pressure regulating valves.
d)Â Â Â Â Â Â Â Â Product Storage Tanks or Vats:Â Storage tanks or vats shall be
fully enclosed or tightly covered and well insulated. The entire interior
surface, agitator and all appurtenances shall be accessible for thorough
cleaning and inspection. Any opening at the top of the tank or vat including
the entrance of the shaft shall be protected against the entrance of dust,
moisture, insects, oil, or grease. The sight glasses, if used, shall be sound,
clear, and in good repair. Vats which have hanged covers shall be so designed
that moisture or dust on the surface cannot enter the vat when the covers are
raised. If the storage tanks or vats are equipped with air agitation, the
system shall be of an approved type and properly installed in accordance with
the 3-A Accepted Practices for Supplying air Under Pressure. Storage tanks or
vats intended to hold product for longer than approximately 8 hours shall be
equipped with refrigeration and/or have insulation. All new storage tanks or
vats shall meet the appropriate 3-A Sanitary Standards and shall be equipped
with thermometers in good operating order.
e)Â Â Â Â Â Â Â Â Separators:Â All product contact surfaces of separators shall
be free from rust and pits and insofar as practicable shall be a stainless
steel or other equally noncorrosive metals.
f)Â Â Â Â Â Â Â Â Coil or Dome-type Batch Pasteurizers:Â Coil or dome-type batch
pasteurizers shall be stainless steel lined and if the coil is not stainless
steel or other equally noncorrosive metal it shall be tinned over the entire
surface. Sanitary seal assemblies at the shaft ends of coil vats shall be of
the removable type, except that existing equipment not provided with this type
gland will be acceptable if the packing glands are maintained and operated
without contaminating the milk or milk products. New or replacement units
shall be provided with removable packing glands. Dome-type pasteurizer
agitators shall be stainless steel except that any nonmetallic parts shall meet
3-A Sanitary Standards for Plastic or Rubber and Rubberlike Materials, as applicable.Â
Each pasteurizer used for heating product at 165º F. or lower for 30 minutes or
less shall be equipped with space heating equipment and the necessary
thermometers to insure a temperature at least 5º F. above that required for
pasteurization of the product. There shall be a means of controlling the
temperature of the heating medium. Batch pasteurizers shall have temperature
indicating and recording devices.
g)Â Â Â Â Â Â Â Â High-temperature, Short-time (HTST) Pasteurizers:Â When
pasteurization is intended or required, an approved timing pump or device
recorder-controller, automatic flow diversion valve and holding tube or its
equivalent, if not a part of the existing equipment, shall be installed on all
HTST equipment used for pasteurization, to assure complete pasteurization (21
CFR 133 and 135). The entire facility shall meet the 3-A Accepted Practices
for the Sanitary Construction, Installation, Testing, and Operation of
High-Temperature, Short-Time Pasteurizers. After the HTST unit has been tested
according to the 3-A Accepted Practices, the timing pump or device and the
recorder controller shall be sealed at the correct setting to assure
pasteurization. Sealing of the HTST unit shall be performed by the
Department. The H.T.S.T. pasteurizer shall be tested initially and annually by
the Department, also whenever any alteration or replacement is made which
affects the proper operation of the instrument or device. When direct steam
pasteurizers are used, the steam, prior to entering the product, shall be conducted
through a steam strainer and a steam purifier equipped with a steam trap and
only steam meeting the requirements for culinary steam shall be used (See
Section 785.410(d)).
h)Â Â Â Â Â Â Â Â Thermometers and Recorders
1)Â Â Â Â Â Â Â Â Indicating Thermometers:
A)       Long-stem indicating thermometers which are accurate within 0.5º
F., plus or minus, for the applicable temperature range, shall be provided for
checking the temperature of pasteurization and cooling of products in vats and
checking the accuracy of recording thermometers.
B)Â Â Â Â Â Â Â Short-stem indicating thermometers, which are accurate within
0.5º F., plus or minus, for the applicable temperature range, shall be
installed in the proper stationary position in all HTST, and dome-type
pasteurizers. Storage tanks where temperature readings are required shall have
thermometers which are accurate within 2.0º F., plus or minus.
C)Â Â Â Â Â Â Â Air-space indicating thermometers, where applicable, which are
accurate within 1.0º F., plus or minus, for the proper temperature range shall
also be installed above the surface of the products pasteurized in vats, to
make certain that the temperature of the foam and/or air above the products
pasteurized also received the required minimum temperature treatment.
2)Â Â Â Â Â Â Â Â Recording Thermometers:
A)       HTST recording thermometers that are accurate within 1º F.,
plus or minus, for the applicable temperature range shall be used on each heat
treating, pasteurizing, or sterilizing unit to record the heating process.
B)       Additional use of recording thermometers accurate within 2º F.,
plus or minus, shall be required where a record of temperature or time of
cooling and holding is of significant importance.
i)Â Â Â Â Â Â Â Â Â Surface Coolers:Â Surface coolers shall be equipped with
hinged or removable covers, for the protection of the product. The edges of
the fins shall be so designed as to divert condensate on nonproduct contact
surfaces away from product contact surfaces. All gaskets or swivel connections
shall be leak proof.
j)Â Â Â Â Â Â Â Â Â Plate-type Heat Exchangers:Â Plate-type heat exchangers shall
meet the 3-A Sanitary Standards for Construction and Installation. All gaskets
shall be tight and kept in good operating order. Plates shall be opened for
inspection by the operator at sufficiently frequent intervals to determine if
the equipment is clean and in good repair (e.g. free of dents, holes, broken
gaskets and cracks). A cleaning regimen shall be posted to insure cleaning
procedures between inspection periods.
k)Â Â Â Â Â Â Â Â Internal Return Tubular Heat Exchangers:Â Internal return
tubular heat exchangers shall meet the 3-A Sanitary Standards for Construction
and Installation.
l)Â Â Â Â Â Â Â Â Â Pumps:Â Pumps used for milk and dairy products shall be of
the sanitary type and constructed to meet 3-A Sanitary Standards. Unless pumps
are specifically designed for effective cleaning in place they shall be
disassembled and thoroughly cleaned after use.
m)Â Â Â Â Â Â Â Homogenizers:Â Homogenizers and high pressure pumps of the
plunger type shall meet the 3-A Sanitary Standards.
n)Â Â Â Â Â Â Â Â New Equipment and Replacements:Â New equipment and
replacements, including all plastic parts and rubber and rubberlike materials
for parts and gaskets having product contact surfaces, shall meet the 3-A
Sanitary Standards. If equipment or replacements are not approved by 3-A
Sanitary Standards, such equipment and replacements shall meet the general
requirements of this section.
o)Â Â Â Â Â Â Â Â Vacuum Chamber:Â The vacuum chamber, as used for flavor
control, shall be made of stainless steel or other equally noncorrosive metal.Â
The unit shall be constructed to facilitate cleaning and all product contact
surfaces shall be accessible for inspection. It shall be equipped with a
vacuum breaker and a check valve at the product discharge line. Only steam
which meets the requirements for culinary steam shall be used (See Section
785.410(d)). The incoming steam supply shall be regulated by an automatic
solenoid valve which will cut off the steam supply in the event the flow
diversion valve of the HTST pasteurizer is not in the forward flow position.Â
Condensers when used shall be equipped with a water level control and an
automatic safety shutoff valve.