77 Ill. Adm. Code 800.1200
Design of Buildings
Section 800
Section 800.1200Â Design of
Buildings
a)Â Â Â Â Â Â Â Â Every foundation, floor, wall, ceiling, roof and stairway
shall be sound and capable of supporting the load for which it was intended or
designed. The structure shall support all occupants permitted by Section
800.1200(d).
b)Â Â Â Â Â Â Â Â Every roof and exterior wall shall be constructed and
maintained to keep rain, sleet and snow from the interior of buildings used by
patrons for living or sleeping purposes.
c)Â Â Â Â Â Â Â Â Permanent buildings shall be separated by at least 10 feet
from other permanent buildings and at least 25 feet from any public road.
d)Â Â Â Â Â Â Â Â Each room for sleeping purposes shall contain at least 70
square feet of floor space. When occupied by two or more persons, each
sleeping room shall contain at least 40 square feet of floor space per occupant
if single deck bunks are used and at least 30 square feet of floor space per
occupant if double deck bunks are used. There shall be at least 30 inches of
clear space above all beds and beds shall not be located within 30 inches of
each other.
e)Â Â Â Â Â Â Â Â Each room used for combined sleeping, cooking and eating
purposes shall contain at least 100 square feet of floor space per occupant.
f)Â Â Â Â Â Â Â Â No building containing two or more sleeping rooms shall have
arrangements such that access to a sleeping room or access to toilet facilities
requires the occupants to pass through another sleeping room.
g)Â Â Â Â Â Â Â Â At least one half of the floor area in a sleeping room used
for determining maximum occupancy shall have a ceiling height at least seven
feet, and no floor area with a ceiling height of less than five feet shall be
used in determining maximum occupancy.
h)Â Â Â Â Â Â Â Â Every room used for sleeping shall have at least one openable
window or skylight or mechanical device for ventilation. The openable area of
the window shall be screened and shall equal at least four percent of the floor
area.
i)Â Â Â Â Â Â Â Â Â Every sleeping room shall have a window area equivalent to eight
percent of the floor area or artificial lighting equivalent to 2 lumens per
square foot of floor area or 25 watts of incandescent light per 100 square feet
of floor area.
j)Â Â Â Â Â Â Â Â Â All buildings of more than one story where sleeping or living
quarters are located on a floor above ground level shall have at least two
means of exit from upper floors and shall have at least one easily accessible
fire extinguisher (i.e., located not more than five (5) feet off the ground
with no objects placed in front of the extinguisher that blocks access to it)
in working order on each floor.
k)Â Â Â Â Â Â Â Â All buildings including those used for sleeping, living, food
preparation or eating shall be kept clean and free of insects and vermin.
l)Â Â Â Â Â Â Â Â Â Each floor level of all permanent buildings used for sleeping
shall be provided with a minimum of one smoke detector constructed, installed
and operated in accordance with the National Fire Protection Association's NFPA
101, :Life Safety Code, 2021 Edition. The requirements of the Smoke Detector
Act shall be met.
m)Â Â Â Â Â Â Â All plumbing shall comply with the requirements of the Illinois
Plumbing Code in effect at the time of installation. The requirements of the
Illinois Plumbing License Law shall be met.