77 Ill. Adm. Code 810.120
Sanitary Facilities
Section 810
Section 810.120Â Sanitary
Facilities
a)        Plumbing. All plumbing shall be in accordance with the
Illinois Plumbing Code which was current at the time of construction.
b)        Shower Facilities. Each youth camp, other than a primitive
camp or a day camp, shall provide showers for the occupants.
1)Â Â Â Â Â Â Â Â A minimum of one shower head shall be provided for each 20
persons or fraction thereof to be accommodated.
2)Â Â Â Â Â Â Â Â An enclosed, dry area shall be provided adjacent to the shower
area for dressing.
3)Â Â Â Â Â Â Â Â The shower room and dressing area floors shall be concrete
with nonslip surface, sloped to drain. No duck boards or mats shall be
permitted.
4)Â Â Â Â Â Â Â Â The shower area shall contain at least seven square feet of
floor space for each shower head.
5)Â Â Â Â Â Â Â Â Showers shall be provided with hot and cold running water
which may be tempered or blended.
6)Â Â Â Â Â Â Â Â Water heaters shall be equipped with pressure-temperature
relief valves. The discharge line from the pressure-temperature relief valve
shall not be reduced in size and shall discharge to atmosphere within six
inches of the floor and shall be directed toward the floor.
c)        Hand Washing Facilities. All youth camps shall be provided
with sinks, lavatories, or group washing stands for hand washing which shall be
located within or near the living quarters of the youth camp.
1)Â Â Â Â Â Â Â Â One lavatory or equivalent shall be provided for each 20
persons or fraction thereof to be accommodated. Where wash basins are provided
instead of lavatories, there shall be one wash basin for each 10 persons or
fraction thereof to be accommodated.
2)Â Â Â Â Â Â Â Â Lavatories, sinks, and wash basins shall drain to systems
specified in Section 810.50.
d)        Toilet Facilities. Each youth camp shall provide toilet
facilities for the occupants.
1)Â Â Â Â Â Â Â Â A minimum of one water closet or one privy seat shall be
provided for each 20 persons or fraction thereof to be accommodated.
2)Â Â Â Â Â Â Â Â Urinals constructed of nonabsorbent materials may be
substituted for male toilet seats on the basis of one urinal for one toilet
seat up to a maximum of one-third of the required toilet seats.
e)        Beds and Bedding. Youth camps which provide beds and bedding
shall comply with the following:
1)        A separate bed shall be provided for each camper. A double
deck bunk bed shall be considered to be two beds.
2)Â Â Â Â Â Â Â Â Sheets and pillow cases, when provided, shall be laundered at
least each week and before use by each new camper.
3)Â Â Â Â Â Â Â Â Blankets, when provided, shall be laundered at least annually.
4)Â Â Â Â Â Â Â Â Mattresses and pillows, when provided, shall be covered with
removable covers which shall be washed before use by each new camper; however,
plastic covered mattresses and pillows shall not require covers.
5)Â Â Â Â Â Â Â Â Mattress bags, when provided, shall be laundered at least
annually and before use by each new camper. The mattress filling shall be
changed each time the mattress bag is washed.