77 Ill. Adm. Code 855.390
Materials and Equipment
Section 855
Section 855.390Â Materials
and Equipment
The contractor performing
asbestos abatement in a school shall furnish all labor, materials, and
equipment necessary for completion of the project.
a)Â Â Â Â Â Â Â Â All materials subject to damage shall be stored off the
ground, away from wet or damp surfaces, and under protective cover to prevent
damage or contamination. Replacement materials shall be stored outside of the
work area until abatement is completed.
b)Â Â Â Â Â Â Â Â Damaged and deteriorating materials shall not be used and
shall be removed from the premises.
c)Â Â Â Â Â Â Â Â Plastic (polyethylene) sheeting, in sizes to minimize the
frequency of joints, shall be furnished.
d)Â Â Â Â Â Â Â Â Duct tape shall be used for sealing joints of adjacent sheets
of plastic and facilitating attachment of plastic sheets to finished or
unfinished surfaces.
e)Â Â Â Â Â Â Â Â Spray adhesive shall be capable of providing additional
sealing of joints and facilitating attachment of plastic sheeting to finished
or unfinished surfaces where needed.
f)Â Â Â Â Â Â Â Â The surfactant used to produce amended water shall be a
product that is nontoxic, noncarcinogenic, and is not an eye, nose, or skin
irritant.
g)Â Â Â Â Â Â Â Â Airtight and watertight containers shall be provided to
receive and retain any asbestos-containing or contaminated materials for
storage until disposal at a landfill. The containers shall be labeled in
accordance with OSHA regulation 29 CFR 1926.1101(k)(7).
h)Â Â Â Â Â Â Â Â Plastic asbestos disposal bags shall be six mil or equivalent
in thickness and be marked with caution labels in accordance with OSHA
regulation 29 CFR 1926.1101(k)(7).
i)Â Â Â Â Â Â Â Â Â Enclosure materials shall be impact resistant and assembled
to be airtight. Gypsum panels taped at the seams, tongue and groove boards, and
boards with spline joints all meet this requirement. Joints between walls and
ceilings shall be caulked.
j)Â Â Â Â Â Â Â Â Â An encapsulant shall adhere to the fibrous substrate with
sufficient penetration to prevent separation of the sealant from the
asbestos-containing materials (see Section 855.240).
k)Â Â Â Â Â Â Â Â Negative air pressure equipment shall be in compliance with
ANSI Z9.2 (1991), Local Exhaust Ventilation.
l)Â Â Â Â Â Â Â Â Â Negative air pressure systems shall be operated in accordance
with "Specifications and Operating Procedures for the Use of Negative
Pressure Systems for Asbestos Abatement," Guidance for Controlling Friable
Asbestos-Containing Materials in Buildings, EPA Report Number 560/5-85-024
(1985).