77 Ill. Adm. Code 860.230
Water
Section 860
Section 860.230 Water
a) Potable water shall be provided at each site. The source of
the water shall be either a community public water supply system regulated by
the Illinois Environmental Protection Agency or a system regulated by the
Department. Systems regulated by the Department shall comply with one of the
following:
1) The construction and water quality requirements of the
Drinking Water Systems Code shall be met. (Type B Violation)
2) Water wells shall be located and constructed in accordance
with the Illinois Water Well Construction Code and water well pump installation
shall comply with the Illinois Water Well Pump Installation Code. (Type B
Violation)
3) Surface water supply systems shall be constructed and operated
in accordance with the Surface Source Water Treatment Code. (Type B Violation)
b) The water distribution system shall be subject to the
following requirements:
1) If the system is connected to a community public water supply
system and has one main water meter, the distribution system beyond the main meter
shall be subject to the requirements of the Drinking Water Systems Code and the
Illinois Plumbing Code and shall be installed and maintained by a licensed
Illinois plumber in accordance with the Illinois Plumbing License Law. (Type B
Violation)
2) If the system is connected to a community public water supply
system and the residents are billed by the manufactured home community owner
for the water based on the readings from the meters at each site, the
manufactured home community owner is considered a water supplier and is subject
to the requirements of the Illinois Environmental Protection Agency. The
distribution system up to the individual service line to each home shall be
subject to the requirements of the Illinois Environmental Protection Agency. (Type
B Violation)
3) If the park is served by its own community public water supply
system, or the manufactured home community is connected to a community public
water supply without a main meter for the manufactured home community, the
distribution system up to the individual service line to each home shall be
subject to the requirements of the Illinois Environmental Protection Agency. (Type
B Violation)
c) Water distribution systems not subject to the requirements of
the Illinois Environmental Protection Agency shall be designed and constructed
in compliance with the requirements of the Drinking Water Systems Code and the
Illinois Plumbing Code and shall be installed and maintained by a licensed
Illinois plumber in accordance with the Illinois Plumbing License Law. (Type B
Violation)
1) The following additional requirements shall be met for all
distribution systems:
A) The distribution system shall supply water to each site at a
minimum pressure of 20 pounds per square inch during periods of peak usage. A
pressure reducing valve shall be installed if the pressure exceeds 80 pounds
per square inch. The distribution pipe shall be looped, whenever possible, and
dead end mains shall be equipped with flush hydrants or equivalent. (Type A
Violation)
B) All water lines under the home shall be protected from
freezing. The manufactured home community rules (Section 860.410) shall
address the resident's responsibility concerning protection of water lines from
freezing. If heat tapes are used, they must be listed for use for manufactured
homes and installed according to the manufacturer's instructions. (Type A
Violation)
2) The following requirements shall be met for distribution
systems constructed after July 1, 1998:
A) The water main distribution pipe shall be sized in accordance
with Table B and be of approved material listed in the "Standard
Specifications for Water and Sewer Main Construction in Illinois", 2014
Edition. (Type A Violation)
B) Water mains must include flush hydrants or equivalent at a
minimum of every 600 feet and at dead ends of piping. Flushing hydrants shall
be sized to provide flows that will give a mean velocity of at least 2½ feet
per second in the distribution piping being flushed. (Type A Violation)
C) Each site shall be served with a separate minimum ¾ inch inside
diameter service connection. (Type A Violation)
D) All water risers shall be at least ¾ inch inside diameter,
terminate at least 4 inches above the finished grade, and be separated at least
10 feet horizontally from the sewer riser. (Type B Violation)
E) An approved shut-off valve shall be provided near the street or
site line for installations after July 1, 1998. (Type A Violation)
d) The manufactured home community owner shall be responsible for
sampling of the water supply system and submitting the results as required by
the Department. Routine water sampling will not be required by the Department
for water supplies regulated by the Illinois Environmental Protection Agency. (Type
A Violation)
e) If the water distribution system is not regulated by the
Illinois Environmental Protection Agency, the following requirements shall be
met. When a break occurs in the manufactured home community's distribution
system or the pressure in the water distribution system is below the minimum 20
pounds per square inch, the Department's regional office (see Section
860.Appendix A) shall be notified by telephone within 24 hours or the next
business day. The affected residents shall be notified immediately by the
manufactured home community management of the need to boil their water for
three minutes before drinking it. A sign shall be posted at the entrance(s) of
the manufactured home community. The Department shall advise the manufactured
home community when the boil order can be lifted.
f) All water leaks in the water distribution system, including
those under the manufactured home, shall be repaired within 72 hours after
notification from a resident or a Department representative. (Type A Violation)
g) Notification of planned water supply interruptions for periods
greater than one hour shall be provided by the manufactured home community
management to the residents affected by the interruption. (Type A Violation)