Section 870.TABLE H   Multi-Section Fastening Schedule CONNECTOR LOCATION FASTENER SIZE FASTENER ANGLE FASTENER SPACING Roof ridge beam connection ½ inch carriage bolts 90 degrees 48 inches on center Roof ridge beam connection ⅜ inch lag screws with washers 45 degrees or less 24 inches on center Roof rafter connection 4 inch by 10 inch 18 gauge straps with 10-10d nails 90 degrees 48 inches on center Floor rim joist connection ⅜ inch lag screws with washers 45 degrees or less 32 inches on center Floor connection Marriage clips 90 degrees Where installed