77 Ill. Adm. Code 880.15
Incorporated and Referenced Materials
Section
880.15Â Incorporated and Referenced Materials
a)Â Â Â Â Â Â Â Â Incorporations
by Reference
All modular dwellings and mobile
structures constructed for location in Illinois shall conform to the standards
of the nationally recognized organizations listed in this subsection (a) and
the standards listed in this subsection (a) are hereby incorporated by
reference in this Part. These standards do not include amendments or editions
after the date specified. Copies of the incorporated codes are available for
public inspection at the Illinois Department of Public Health, Division of
Environmental Health, 525 West Jefferson Street, Springfield, IL Â 62761, 217-782-5830.
1)Â Â Â Â Â Â Â Â Building
A)Â Â Â Â Â Â Â All
one and two family modular dwellings and duplex mobile structures shall conform
to the International Residential Code, 2018 Edition, published by:
International Code Council, Inc.
(ICC)
200
Massachusetts Avenue, NW, Suite 250
Washington, DC Â 20001
202-
370-1800
Chapters 25 through 32 and Section
R313 are excluded from this incorporation.
B)Â Â Â Â Â Â Â All
multiple family modular dwellings and mobile structures other than duplex
dwelling units shall conform to the International Building Code, 2018 Edition,
published by:
International Code Council, Inc.
(ICC)
200 Massachusetts Avenue, NW, Suite
250
Washington, DCÂ 20001
202-370-1800
2)Â Â Â Â Â Â Â Â Electrical
A)Â Â Â Â Â Â Â All
one and two family dwellings and duplex mobile structures shall conform to the
International Residential Code, 2018 Edition.
B)Â Â Â Â Â Â Â All
multiple family modular dwellings and mobile structures other than duplex
dwelling units shall conform to the National Electrical Code, 2017 edition
(NFPA 70-2017), published by:
National Fire Protection
Association (NFPA)
1 Batterymarch Park
Quincy, MA Â 02269-7471
800-344-3555
3)Â Â Â Â Â Â Â Â Energy.Â
All modular dwellings and mobile structures shall conform to the Illinois
Energy Conservation Code, 2018 Edition, published by:
Capital Development Board
401 South Spring Street
Springfield, IL Â 62706
217-782-2864
4)Â Â Â Â Â Â Â Â Mechanical
A)Â Â Â Â Â Â Â All
one and two family modular dwelling units and duplex mobile structures shall
conform to the International Residential Dwelling Code, 2018 Edition, and the
International Fuel Gas Code, 2018 Edition.
B)Â Â Â Â Â Â Â All
multiple family modular dwellings and mobile structures shall conform to the
International Mechanical Code and International Fuel Gas Code, 2018 Edition,
published by:
International Code Council, Inc.
(ICC)
200 Massachusetts Avenue, NW, Suite
250
Washington, DCÂ 20001
202-370-1800
5)Â Â Â Â Â Â Â Â Personnel.
Inspection agencies shall conform to the personnel requirements of ASTM E 541-10
(2010), Standard Specification for Agencies in System Analysis and Compliance
Assurance for Manufactured Building, published by:
American Society for Testing and
Materials
100 Barr Harbor Drive
West Conshohocken, PA Â 19428
6)Â Â Â Â Â Â Â Â General
A)Â Â Â Â Â Â Â General
Exceptions to the Incorporated Codes
i)Â Â Â Â Â Â Â Â Â The
requirements of the incorporated codes pertaining to the administration and
enforcement of the codes shall not apply because this Part and the Act address
those areas. All definitions remain unchanged, except that terms such as
"building official" and "authority having jurisdiction" shall
mean the Department.
ii)Â Â Â Â Â Â Â Â The
Department is responsible for regulating the portion of the modular dwelling
unit and mobile structure constructed at the factory. The on-site assembly
shall not cause the unit to be in violation of any of the incorporated or
referenced codes. Such aspects as the location of the units, their foundations
and the installation of on-site utilities shall be subject to regulation by the
local jurisdiction.
iii)Â Â Â Â Â Â Â The
provisions of the incorporated codes are not intended to limit the appropriate
use of materials, appliances, equipment or methods of design or construction
not specifically prescribed by the incorporated codes. Research reports from a
model code organization or nationally recognized testing agency approving the
use of alternate materials or methods of construction shall be considered
sufficient evidence of compliance with the requirements of the incorporated or
referenced codes subject to the limitations and conditions of the testing
agency's written approval. All requests for approval of alternatives shall be
submitted in writing to the Department. The Department shall respond to those
requests in writing within 30 days after receipt.
iv)Â Â Â Â Â Â Â No
revisions to the applicable code and requirements shall apply retroactively.
The Department shall notify all manufacturers and approved inspection agencies
of all code changes as reflected by amendments to this Part. Previously
approved units manufactured on or after December
28, 2005 shall obtain new plan approval prior to their construction.
B)Â Â Â Â Â Â Â Exceptions
to Specified Design Criteria. The following provisions shall apply to the
design and construction of all modular dwellings and mobile structures:
i)Â Â Â Â Â Â Â Â Â Roofs
shall be designed for a minimum live load of 30 pounds per square foot.
ii)Â Â Â Â Â Â Â Â Horizontal
wind pressure shall be considered as acting on the gross area of the vertical projection
and shall be considered for design purposes as not less than 25 pounds per
square foot to a height of 30 feet and 30 pounds per square foot for heights
over 30 feet above grade.
iii)Â Â Â Â Â Â Â Carpet
or padding shall not be placed under any load-bearing walls.
iv)Â Â Â Â Â Â Â Ceiling
material that is placed directly above top plates of bearing walls shall be of
compressive strength capable of transmitting the required design loads without
any type of failure to transmit the required ceiling and roof loads, or provisions
shall be made to transfer the loads through material of sufficient strength.
v)Â Â Â Â Â Â Â Â Modular
dwellings and mobile structures shall be fastened together at the floor system
and roof systems to minimize any movement between multiple units.
vi)Â Â Â Â Â Â Â The
following design parameters shall be used for the energy criteria in the use of
the International Energy Conservation Code for all modular dwellings and mobile
structures:
•          The
winter design dry-bulb temperature shall be 4º Fahrenheit.
•          The
summer design dry-bulb temperature shall be 93º Fahrenheit.
•          The
summer wet-bulb temperature shall be 77º Fahrenheit.
•          The
degree days heating shall be 6800.
vii)Â Â Â Â Â Â Modular
dwelling stair maximum riser height and minimum tread depth. The maximum riser
height shall be 8¼ inches. The minimum tread depth shall be 9 inches.
b)Â Â Â Â Â Â Â Â Materials
Referenced in this Part
1)Â Â Â Â Â Â Â Â Building
Standards
A)Â Â Â Â Â Â Â Capital
Development Board, Illinois Accessibility Code (71 Ill. Adm. Code 400)
B)Â Â Â Â Â Â Â Illinois
Architecture Practice Act of 1989 [225 ILCS 305] Professional Engineering
Practice Act of 1989 [225 ILCS 325] Structural Engineering Practice Act of 1989
[225 ILCS 340]
2)Â Â Â Â Â Â Â Â Fire
Safety
A)Â Â Â Â Â Â Â Office
of the State Fire Marshal, Fire Prevention and Safety (41 Ill. Adm. Code 100)
B)Â Â Â Â Â Â Â Smoke
Detector Act [425 ILCS 60]
3)Â Â Â Â Â Â Â Â Plumbing
Department of Public Health,
Illinois Plumbing Code (77 Ill. Adm. Code 890)
4)Â Â Â Â Â Â Â Â Schools
State Board of Education,
Health/Life Safety Code for Public Schools (23 Ill. Adm. Code 180)
5)Â Â Â Â Â Â Â Â Travel
Travel expenses shall be reimbursed
in accordance with Central Management Services/Governor's Travel Control Board,
Travel (80 Ill. Adm. Code 2800)