77 Ill. Adm. Code 890.680
Lavatories
Section 890
Section 890.680 Lavatories
a) Waste Outlets. Wastes shall have a strainer or stopper and
have a waste outlet at least 1¼ inches in diameter.
b) Lavatory Faucets. All lavatory faucets shall have air gaps as
specified in Appendix A.Table C.
c) When metering faucets are located on lavatories in public
restrooms, they shall be adjusted to remain open for a minimum of 10 seconds and
shall comply with the water consumption requirements of ASME/ANSI 112.18.1.
Metering faucets shall be designed for hot and cold, tempered and cold, or
tempered water only.
d) Fixture Calculation. Eighteen lineal inches of wash sink or 18
inches of a circular basin, when provided with water outlets for the space,
shall be considered equivalent to one lavatory. (See Appendix F.Illustration
B.)
e) Water Temperature. All lavatory faucets for public use shall
be provided with an automatic safety water mixing device to prevent sudden
unanticipated changes in water temperature or excessive water temperatures. The
automatic safety water mixing device shall comply with ASSE 1070 or 1017 in
accordance with Section 890.210, and shall be adjusted to a maximum setting of 110
degrees Fahrenheit, at the time of installation. Exception: Units constructed
in accordance with Section 890.1220(a)(9)(B) may be used in lieu of an
automatic safety water mixing device to provide hot or tempered water to public
lavatories.