77 Ill. Adm. Code 890.810
Minimum Number of Plumbing Fixtures
Section 890
Section 890.810 Minimum
Number of Plumbing Fixtures
a) Minimum Number of Fixtures Required. Plumbing fixtures shall
be provided, for each building type and occupant load, in the minimum numbers
shown in Appendix A.Table B, Minimum Number of Plumbing Fixtures, except as
noted in footnote 2. Questions concerning the minimum numbers of fixtures
required for building types not listed in Appendix A.Table B, shall be referred
to the Department in writing prior to construction for a decision concerning
the minimum numbers (and types) of plumbing fixtures required. The
Department's decision shall be in writing based on Appendix A.Table B.
1) Building Classification. For purposes of this Part, buildings
shall be classified according to the types shown in Appendix A.Table B.
Buildings that incorporate more than one type of building use or occupancy, as
classified by the Department, shall provide the combined numbers of fixtures
required for the individual uses. Individual businesses within the same
building or within an enclosed mall may share public or employee restroom
facilities, provided that the access to the restrooms does not require trespass
on adjoining businesses or leased space. Restrooms shall be open at all times
when any individual business within the same building or within an enclosed
mall is open.
2) Occupant Load. For those building types for which the minimum
number of plumbing fixtures required in Appendix A.Table B is dependent upon
the building's occupant load, the occupant load shall be the estimated total
occupant load. If the building's occupant load is not known or determinable,
the following shall be used to estimate the total occupant load:
A) In assembly places (sports arenas, stadiums, convention
centers, theaters, auditoriums, gymnasiums or other facilities for spectator
events); worship places and funeral homes; schools; office buildings; food
service establishments; and mercantile units, the total occupant load
(employees and public users of the facility) shall be based on the capacity of
the rooms or spaces used for assembly purposes or other intended occupancy and
shall be determined as follows:
i) In rooms or spaces with fixed seating, the occupant load
shall be the actual number of seats provided. When no divisions between seats
are provided (e.g., benches or pews), fixed seating shall be computed assuming
18 inches per person.
ii) In rooms or spaces without fixed seating, the occupant load
shall be determined by dividing the gross floor area by the estimated floor
area per person shown in the following table:
Building Type or Occupancy
Floor
Area per
Person
(Sq. Ft.)
Assembly Places – Facilities for Spectator Events; Worship Places and
Funeral Homes
50
Museums, Libraries, Exhibition Areas and Similar Uses
50
Schools
50
Day Care Centers
70
Office Buildings
200
Food Service Establishments, Clubs, Taverns, and Other Eating/Drinking
Facilities
30
Mercantile Units, Except Grocery Stores, Auction Houses, Sale Barns,
Car Auction Centers, and other similar Mercantile Units
− First Floor
− All Other Floors
100
120
Combination Grocery Store/Non-Grocery Mercantile Units
150
Mercantile Units, such as Auction Houses, Sale Barns, Car Auction
Centers, and other similar Mercantile Units
40
Grocery Stores
200
Storage/Shipping Area
400
Power Plants/Industrial Units
500
iii) For a drive-in food service establishment, the occupant load
shall be considered as equal to the number of parking stalls.
B) Dormitories and Institutions. For dormitories, penal
institutions and other residential institutions other than hospitals, the total
occupant load shall be based upon the number of beds in the dormitory or
institution.
C) Restroom Location and Requirements. The required number of
plumbing fixtures for a restroom shall be located within the restroom area and
not in the hallways or vestibules. Lavatories required by Appendix A.Table B
shall be installed in restrooms at a ratio of not less than one lavatory per two
water closets or urinals. (See Footnote 2, Appendix A.Table B.)
b) Required Restroom Facilities and Drinking Fountains
1) Employee Restrooms and Drinking Fountains
A) Restroom facilities and drinking fountains shall be provided
for all employees within each place of employment. The minimum numbers of
fixtures provided shall be based on the maximum number of male and female
employees working at any one time, as shown in Appendix A.Table B. (The numbers
of fixtures required for employees are included in the numbers shown in Table B
for all building types/uses except hospital rooms, penal institutions and other
institutions. The entry in Appendix A.Table B (All Facilities for Employee Use)
shall be used to determine the minimum number of fixtures required for
employees in hospitals, penal and other institutions, and all other buildings/facilities
that do not appear in Appendix A.Table B.)
i) If there are more than five employees working at any one
time, separate restrooms for men and women shall be provided.
ii) If there are no more than five employees working at any time,
one restroom may serve both sexes. A restroom shall have a minimum of one water
closet and one lavatory.
iii) For schools, day care centers and office buildings, the
employee restrooms and drinking fountains shall be located on the same floor or
one floor above or below each location where employees regularly work.
iv) Individual businesses within the same building or within an
enclosed mall may share public/employee restroom facilities, provided that the
access to the restrooms does not require trespass on adjoining business or
leased space. The restrooms shall be designed for the combined occupant load
of the individual businesses served, be open at all times when any individual
business is open, and be located no more than 300 feet from the entrance of
each business served. Exception: Any food service establishment that sells or
serves food or beverages to be consumed on its premises or within the
building/mall shall be located no more than 100 feet from the shared
public/employee restrooms and shall be on the same floor.
v) Kiosks, which are free-standing places of employment, that
have five or fewer employees at any time who have access to public restrooms
and a drinking fountain within 300 feet of the kiosks, shall not be required to
have employee restroom facilities or a drinking fountain.
B) If public restrooms and drinking fountains are also required
for the building type, employees may share the restrooms and drinking fountains
with the public, provided that the numbers of fixtures are sufficient for the
combined numbers of males and females and the restrooms and drinking fountains are
provided within the place of employment (and within the required location for
schools, day care centers and office buildings).
2) Public Restrooms and Drinking Fountains
A) General Requirements
i) Buildings with 5,000 square feet of gross public area or with
occupancies of 100 or more persons shall provide public restrooms and drinking
fountains as shown in Appendix A.Table B. Buildings other than those exceptions
in subsection (b)(2)(B), with less than 5,000 square feet of gross public area,
or with occupancies of fewer than 100 persons, need not provide public
restrooms and drinking fountains.
ii) Individual businesses within the same building or within an
enclosed mall, may share public/employee restroom facilities, provided that the
access to the restrooms does not require trespass on adjoining business or
leased space. The restrooms shall be designed for the combined occupant load
of the individual businesses served, always be open when any individual
business is open or when employees are present, and be located no more than 300
feet from the entrance of any business served. Exception: Any food service
establishment that sells food or beverages to be consumed on its premises or
within the building/mall shall be located no more than 100 feet from the shared
public/employee restrooms and shall be on the same floor.
iii) When public restroom facilities are required by this Part,
separate facilities for males and females shall be provided. If additional
public restroom facilities are provided in excess of the minimum requirements
of this Part, they shall comply with one of the following:
• For each additional two water closets or urinals installed in
a restroom, one additional lavatory shall be installed in that restroom.
• Unisex restrooms shall not have more than one water closet
and one lavatory and the option of one urinal.
iv) Plumbing shall meet the requirements of the Illinois
Accessibility Code.
B) Additional Requirements for Special Building Types
i) All food service establishments that sell or serve food or beverages
to be consumed on the premises (regardless of their gross area) shall provide
readily accessible restroom facilities for the public. If public restrooms are
not provided within the premises of the food service establishment, they shall
be located within the same building, on the same floor/level and within 100
feet of an entrance to the food service establishment, and they shall be
available for public use at all times that the food service establishment is
open. Exception: Food service establishments with no more than 10 combined
employees and seats (for patrons) at any one time need not provide public
restrooms, provided that the employee restrooms are accessible and made
available to the public.
ii) All businesses selling motor vehicle fuel to the public
(regardless of their gross area) shall provide at least one public restroom for
male use and one public restroom for female use. Exception: Facilities that do
not have any employees working as attendants during any part of a 24 hour
period and sell only motor fuel to the public using automated machines need not
provide male/female public restrooms or drinking fountains. One employee
restroom shall be provided for use by maintenance staff when maintenance staff
are present.