77 Ill. Adm. Code 890.APPENDIX A
A Plumbing Materials, Equipment, Use Restrictions and Applicable Standards
Section 890
Section 890.APPENDIX A Â Â Plumbing
Materials, Equipment, Use Restrictions and Applicable Standards
Section 890.TABLE EÂ Â
Drainage Fixture Units (D.F.U.) Per Fixture Group
Type
of Fixture
D.F.U./Fixture (Load)
Minimum Size of Trap
2
(inches)
Bathroom groups:
1 tank water
closet, 1 lavatory
with 1¼ inch
trap and 1
bathtub
1
or shower stall
7
1¼
1 water
closet with flush valve, 1
lavatory
with 1¼ inch trap and 1
bathtub or
shower
1
11
Bathtub (with or without
overhead shower)
1
2
1½
Bathtub
1
3
2
Bidet
2
1½
Clothes washer, automatic
3
2
Dental unit or cuspidor
1
1¼
Drinking fountain
½
1
Dishwasher
2
,
domestic
2
1½
Floor drains
See Appendix A, Table F
2
Lavatories:
Lavatory
1
1¼
Lavatory
2
1½
Lavatory,
barber, beauty parlor
2
1½
Lavatory,
dental
1
1¼
Lavatory,
surgeon's
2
1½
Laundry tray (1 or 2
compartments)
2
1½
Type
of Fixture
D.F.U./Fixture (Load)
Minimum Size of Trap
2
(inches)
Shower stall
3
2
Showers (group) per head
2
3
2
Sinks:
Combination
sink and tray
3
1½
Combination
sink and tray with
food-disposal
unit
4
Separate Traps
1½
Flushing
rim (with valve)
8
3
Kitchen
sink, domestic
2
1½
Kitchen
sink, domestic, with food-waste
grinder
3
Separate Traps
1½
Pot,
scullery, etc.
2
4
1½
Service (P
trap)
3
3
Service (P
trap)
2
2
Surgeon's
3
1½
Wash sink
2
(circular or multiple),
each set
of faucets
2
1½
Urinals:
Urinal,
pedestal, siphon jet, blowout
8
2
Urinal
stall
3
2
Urinal,
wall integral trap
3
2
Urinal,
wall P trap, exposed
2
1½
Water closets:
Tank
operated
4
3
Valve-operated
8
3
1
A shower head over a bathtub does not
increase the fixture value.
2
See Appendix A:Â Table F and Section
890.1330(b) for method of determining unit values of fixtures not listed in this
Table or for rating of devices with intermittent flows.