77 Ill. Adm. Code 905.APPENDIX A

A Illustrations and Exhibits

Last amended: 2013Year: 2026Length: 254 wordsOfficial source
Section 905.APPENDIX Aย ย  Illustrations and Exhibits Section 905.ILLUSTRATION C ย ย List of Approved Plastic Pipe for Private Sewage Disposal System TYPES OF PIPES ASTM STANDARD BUILDING SEWER 1 OR COMMON COLLECTOR SEWER LINES 1 ALL SUBSURFACE SEEPAGE SYSTEMS 5 ft. from building to septic-aeration tank to 5 ft. beyond the septic tank, aeration tank or distribution box Additional treatment facilities and sand filter distribution lines and collection lines ABS (DWV Schedule 40) F628-06 x x x ABS (DWV Schedule 40) D2661-06 x x x ABS D1527-99 (2005) x x x ABS (Sewer Pipe) D2751-05 x 2 x 2 x 2 PVC D1785-06 x x x PVC (DWV Schedule 40) D2665-07 x x x PVC (DWV Schedule 40) F891-04 x x x PVC (Type PSM) (SDR 35) D3034-06 x 2 x 2 x 2 PVC (Sewer & Drain PS-50) F891-04 x x x PVC (Sewer & Drain PS-25) F891-04 x x PVC (Corrugated-Smoothwall) F949-06 x x PVC (Std. or Perforated) D2729-03 x x PE (Smoothwall) R810-07 x x AASHTO Standard M252-06 PE (Corrugated-Perforated) F405-05 (Heavy Duty Only) x PE (Corrugated-(Perforated) F667-06 x x โ€“ Indicates approved use. l Plastic materials shall not be co-mingled within this area except through the use of proper adapters. (See Illinois Plumbing Code.) When the building sewer is of a type of material that is different from the building drain, proper transition fittings shall be used. 2 Pipe shall be SDR (Standard Dimension Ratio) 35 only. Note: The last 2 numbers of the ASTM Standard indicate the date of the edition.