77 Ill. Adm. Code 905.APPENDIX A

A Illustrations and Exhibits

Last amended: 2013Year: 2026Length: 85 wordsOfficial source
Section 905 Section 905.APPENDIX A   Illustrations and Exhibits Section 905.ILLUSTRATION I   Seepage Field Construction Section 905.EXHIBIT A   Gravel System Trench length, maximum length from point of discharge into seepage trench 100 feet Trench bottom, minimum width 8 in. Trench bottom, maximum width 36 in. Trench bottom, minimum depth 18 in. Trench bottom, maximum depth 36 in. Trench bottom, slope level Distribution line, minimum diameter 4 in. Distribution line, minimum earth cover 6 in. Distribution line, maximum earth cover 24 in. Distribution line, maximum slope level