83 Ill. Adm. Code 600.310

Test and Allowable Error

Year: 2026Length: 231 wordsOfficial source
Section 600 Section 600.310  Test and Allowable Error a)         The accuracy of a water meter shall be tested by comparing the actual amount of water passing through it with the amount indicated on the dial. b)         The test shall be conducted in accordance with the standards for testing Cold Water Meters as prescribed by the American Water Works Association (AWWA C705-60) with quantities and flows for positive displacement meters as follows: TEST FLOWS (G.P.M.) & QUANTITY MINIMUM INTERMEDIATE MAXIMUM Size of Flow QUANTITY FLOW QUANTITY FLOW QUANTITY meter G.P.M. Gal. Cu.Ft. G.P.M. Gal. Cu.Ft. G.P.M. Gal. Cu.Ft. ⅝" ¼ 10 1 2 10 1 15 100 10 ¾" ½ 10 1 3 10 1 25 100 10 1" ¾ 10 1 4 10 1 40 100 10 1½" 1½ 100 10 8 100 10 80 1000 100 2" 2 100 10 15 100 10 120 1000 100 3" 4 100 10 20 100 10 250 1000 100 4" 7 100 10 40 100 10 350 1000 100 6" 12 100 10 60 100 10 700 1000 100 No meters shall be placed in service when the accuracy is different than follows: NEW METERS REPAIRED METERS MINIMUM RANGE 95-101.5% 90-101.5% INTERMEDIATE RANGE 98.5-101.5% 98.5-101.5% MAXIMUM RANGE 98.5-101.5% 98.5-101.5% c)         The utility may make such additional tests as it may deem necessary but in a manner that will not unreasonably inconvenience the customer.