83 Ill. Adm. Code 737.630
Transmission Requirements
Section 737.630 Transmission Requirements
Local Providers shall furnish and maintain plant, equipment
and facilities to meet the following minimum transmission standards. The
transmission standards set forth in this Section are based upon measurements
from the network interface at the customer premises through the local loop to a
nominal 48-volt central office and measured at a frequency of 1004 hertz.
a) Local
line analog loops shall have a loop resistance not exceeding the operating
design of the associated central office equipment. Longer loops may be used by
deployment of loop range extenders.
b) All
analog loops are to be maintained to a minimum of 40,000 ohms insulation
resistance.
c) Transmission
loss of analog local loop shall be engineered not to exceed 10.0 dB when
measured in accordance with subsection (a). The local loop transmission loss
shall be adjusted to 10.0 dB or less if it exceeds 10.0 dB.
d) Transmission
loss in analog interoffice trunks shall be engineered not to exceed 7 dB. If
the loss exceeds expected design loss by + or - 3.5 dB, it shall be corrected
to within 1 dB of the design loss.
e) Transmission
loss on analog toll terminating trunks shall be engineered not to exceed 4 dB.
If the loss exceeds expected design loss by + or - 3.5 dB, it shall be
corrected to within 1 dB of the design loss.
f) Transmission
loss on all digital interoffice trunks shall be engineered and maintained not to
exceed 6 dB.
g) Loop current shall be maintained at 20 milliamperes or greater.
h) Power
influence (Ng) shall not exceed 90 dBrnc.
i) Circuit
noise (Nm) shall not exceed 30 dBrnc.