8 Ill. Adm. Code 1000.450
Alarm System
Section 1000.450 Alarm System
a) A
cultivation center shall install, maintain and use a professionally monitored
robbery and burglary alarm system meets the following requirements:
1) At a
minimum, the system shall provide coverage of all facility entrances and exits,
rooms with exterior windows, rooms with exterior walls, roof hatches, skylights
and storage rooms that contain safes.
2) Duress alarm,
which means a silent security alarm system signal generated by the entry of a
designated code into an arming station in order to signal that the alarm user
is being forced to turn off the system.
3) Panic alarm,
which means an audible security alarm system signal generated by the manual
activation of a device intended to signal a life threatening or emergency
situation requiring law enforcement response.
4) Holdup alarm,
which means a silent alarm signal generated by the manual activation of a
device intended to signal a robbery in progress.
5) Automatic
voice dialer, which means any electrical, electronic, mechanical or other
device capable of being programmed to send a prerecorded voice message
requesting dispatch, when activated, over a telephone line, radio or other
communication system to a law enforcement, public safety or emergency services
agency.
6) A
failure notification system that provides an audible, text or visual
notification of any failure in the surveillance system. The failure notification
system shall provide an alert to the cultivation center, within five minutes after
the failure, by telephone, email or text message.
7) The
ability to remain operational during a power outage and ensure all access doors
are not solely controlled by an electronic access panel to ensure that locks
are not released during power outage.
b) The system
shall be inspected and all devices tested annually by a qualified alarm vendor.