8 Ill. Adm. Code 256.40
General Class Permits
Section 256
Section 256.40 General Class
Permits
There shall be 3 types of
general class permits available for issuance by the Department to a facility
owner or operator as defined under subsections (a), (b) and (c). In addition
to completed application forms, a submittal for a general class permit shall
include a location area map, a detailed plot plan of the facility and any
additional information the applicant or Department deems necessary to fully
describe the project.
a) A General Class A lawncare containment permit shall be
available for issuance by the Department for a portable containment area for
use with small pesticide application devices with a device capacity of less
than or equal to 100 gallons of liquid product or 100 pounds of dry product.
The containment area shall measure at least 1.5 times the length and 1.5 times
the width of the application device. The design of the containment area shall
be such that the contained volume shall be a minimum of 25 gallons of liquid or
the volume of the application device, whichever is greater. The containment
area shall be constructed of impervious materials as required by the Act and
shall be compatible with the materials applied by the device. The containment
area design shall provide for the collection and reuse or disposal of the
spills, wash waters and rinsates in accordance with Sections 256.70(a) and
256.80(b) of this Part. This provision for the collection and reuse or
disposal of spills, wash waters and rinsates, in the case of portable
containment structures, does not specifically require the inclusion of a sump.
The use of underground structures, pits or piping for storage or transport of
rinsates, wash water or recycled liquid is prohibited at a facility wishing to
qualify for a General Class A lawncare containment permit. This prohibition
shall not include sumps or wet wells that are used for the transfer of spills,
rinsates or wash waters provided these structures have a detention time of 72
hours or less. Facility owners or operators desiring to construct and operate
a containment area adhering to these requirements shall make application to the
Department for a General Class A lawncare containment permit.
b) A General Class B lawncare containment permit shall be
available for issuance by the Department for a non-portable containment area
for use with small pesticide application device with a device capacity less
than or equal to 100 gallons of liquid product or 100 pounds of dry product.
The containment area shall measure at least 1.5 times the length and 1.5 times
the width of the application device. The design of the containment area shall
be such that the contained volume shall be a minimum of 25 gallons of liquid or
the volume of the application device, whichever is greater. Notwithstanding the
aforementioned volume requirement, if the containment area is not protected
from contact with precipitation, the containment volume shall be not less than
the volume generated by a 6-inch rain storm (a 25-year, 24-hour storm). The
containment volume requirements may be achieved with a curbed containment area
and catch basin or in combination with above ground tanks connected to an
automatic sump pump transfer system or by gravity flow where elevation or
installation allows. The containment area shall be constructed of impervious
materials as required by the Act and shall be compatible with the materials
applied by the application device. The containment area design shall provide
for the collection and reuse or disposal of the spills, wash waters and
rinsates in accordance with Sections 256.70(a) and 256.80(b) of this Part.
Collection and reuse or disposal of spills, wash waters and rinsates, in the
case of non-portable containment structures, specifically requires the
inclusion of a sump in the structure. The use of underground structures, pits
or piping for storage or transport of spills, rinsates, wash waters or recycled
liquid is prohibited at a facility wishing to qualify for a General Class B
lawncare containment permit. This prohibition shall not include sumps or wet
wells that are used for the transfer of spills, rinsates or wash waters
provided these structures have a detention time of 72 hours or less. Facility
owners or operators desiring to construct and operate a non-portable
containment area adhering to these requirements shall make application to the
Department for a General Class B lawncare containment permit.
c) A General Class C lawncare containment permit shall be
available for issuance by the Department for a non-portable containment area
for use with pesticide application devices with device capacities greater than
100 gallons of liquid product or 100 pounds of dry product. The containment
area shall measure at least 1.25 times the length and 1.25 times the width of
the application vehicle or device. Pesticide application devices of a lesser
volume than that described in this subsection may also be used with a
containment area permitted under this subsection. The design of the
containment area shall be such that the containment volume shall be a minimum
of 120 gallons or 120% of the largest applicator tank volumes, whichever is
greater. Notwithstanding the aforementioned volume requirement, if the
containment area is not protected from contact with precipitation, the
containment volume shall be not less than the volume generated by a 6-inch rain
storm (a 25-year, 24-hour storm). The containment volume requirements may be
achieved with a curbed containment area and catch basin or in combination with
above ground tanks connected to an automatic sump pump transfer system or by
gravity flow where elevation or installation allows. The containment area
shall be constructed of impervious materials as required by the Act and shall
be compatible with the materials applied by the applicator. The containment
area design shall provide for the collection and reuse or disposal of the
spills, wash waters and rinsates in accordance with Sections 256.70(a) and
256.80(b) of this Part. This provision for the collection and reuse or
disposal of spills, wash waters and rinsates, in the case of non-portable
containment structures, includes the requirement of a sump in the containment
area. The use of underground structures, pits or piping for storage or
transport of spills, rinsates, wash waters or recycled liquid is prohibited at
a facility wishing to q1ualify for a General Class C lawncare containment
permit. This prohibition shall not include sumps or wet wells which are used
for the transfer of spills, rinsates or wash waters provided these structures
have a detention time of 72 hours or less. Facility owners or operators
desiring to construct and operate a containment area adhering to these
requirements shall make application to the Department for a General Class C
lawncare containment permit.