8 Ill. Adm. Code 256.70
Containment Area Management and Operations
Section 256
Section 256.70 Containment
Area Management and Operations
a) Precipitation accumulation shall never exceed a level that
would impair the holding capacity of the containment area. Such precipitation
accumulation shall be removed from the containment area after each storm and
shall be field applied at agronomic rates, used in a liquid mixing operation,
or otherwise recycled or disposed of in accordance with this Part.
Precipitation accumulation from containment areas shall not be discharged from
the containment area as surface runoff during the application season, except
when the containment structure has been cleaned and rinsed of pesticides in
compliance with subsection (b), and the discharge shall not cause either water
quality violations pursuant to 35 Ill. Adm. Code, Subtitle C or a pesticide
release pursuant to the Environmental Protection Act [415 ILCS 5]. Any
pesticide laden residues, rinsates, and pesticide contaminated wash water that
are to be land applied shall be handled in accordance with the products'
labels. Field application of diluted pesticide solutions is an acceptable use
if the total annual application amounts of the pesticide do not exceed the
pesticide label application rates. Spills, rinsates and pesticide contaminated
wash water may be used to make up the total spray mixture if the mixture does
not exceed the pesticide label application rates. Pesticide, pesticide
residues, rinsates, and pesticide contaminated wash water shall not be disposed
of through storm sewers, sanitary sewer systems, public or private sewage
treatment facilities or wells, waters of the State, nor to land, except as
provided in this Section.
b) Pesticide spills into containment areas shall be recovered
promptly and the structure washed to remove pesticide contamination. Proper
cleaning shall include removal, washing and rinsing of material from the area,
mud pits, sump pits and all interconnected pipes of structures. These
containment areas shall be washed with a biodegradable cleanser, triple rinsed
with a high pressure hose and all standing water removed and disposed of as
provided in subsection (a).
c) Field washing of exterior surfaces of pesticide application
equipment is acceptable at the site of the pesticide application provided no
runoff from the site occurs.
d) Spray application vehicles and equipment that are not cleaned
shall be parked in the containment area or otherwise protected from
precipitation so as to prevent the release of pesticide residues to the
environment.