8 Ill. Adm. Code 50.20
Slaughter Methods; Chemical; Carbon Dioxide
Section 50
Section 50.20 Slaughter
Methods; Chemical; Carbon Dioxide
a) The slaughtering of sheep, calves and swine with the use of
carbon dioxide gas and the handling in connection therewith, in compliance with
the provisions contained in these rules, are hereby designated and approved as
humane methods of slaughtering and handling of such animals under the Act.
b) Administration of gas; required effective; handling:
1) The carbon dioxide gas shall be administered in a chamber in
accordance with these rules so as to produce surgical anesthesia in the animals
before they are shackled, hoisted, thrown, cast, or cut. The animals shall be
exposed to the carbon dioxide gas in a way that will accomplish the anesthesia
quickly and calmly, with a minimum of excitement and discomfort to the
animals. In swine, carbon dioxide may be administered to induce death in the
animals before they are shackled, hoisted, thrown, cast, or cut.
2) The driving or conveying of the animals to the carbon dioxide
chamber shall be done with a minimum of excitement and discomfort to the
animals. Delivery of calm animals to the anesthesia chamber is essential since
the induction, or early phase, of anesthesia is less violent with docile
animals. Among other things this requires that, in driving animals to the
anesthesia chamber, electrical equipment be used as little as possible and with
the lowest effective voltage.
3) On emerging from the carbon dioxide tunnel, the animals shall
be in a state of surgical anesthesia and shall remain in this condition
throughout shackling, sticking and bleeding, except for swine in which death
has been induced by the administration of carbon dioxide. The provisions of 8
Ill. Adm. Code 125.190 and 125.210 and 9 CFR 311.30 (1990) shall apply.
Asphyxia or death from any cause shall not be produced in the animals before bleeding,
except for swine in which death has been induced by the administration of
carbon dioxide.
c) Facilities and procedures:
1) General requirements for gas chambers and auxiliary equipment;
operator: The carbon dioxide gas shall be administered in a chamber which
accomplishes effective exposure of the animal. Two types of tunnels, based on
the same principle, are in common use for carbon dioxide anesthesia. They are
the "U" type tunnel and the "Straight Line" type tunnel,
and are based on the principle that carbon dioxide gas has a higher specific
gravity than air. The tunnels are open at both ends for entry and exit of
animals and have a depressed central section. Anesthetizing or, in the case of
swine, death-inducing, carbon dioxide concentrations are maintained in the
central sections of the tunnels. Effective anesthetization is produced in
these central sections. Animals are driven from holding pens through pathways
constructed of large-diameter pipe or smooth metal and onto continuous conveyor
devices that move the animals through the tunnels. The animals are either
compartmentalized on the conveyors by mechanical impellers synchronized with
the conveyor or they are otherwise prevented from crowding. While impellers
are used to compartmentalize the animals, mechanically or manually operated
gates are used to move the animals onto the conveyors. Surgically anesthetized
animals, or killed swine, are moved out of the tunnels by the same continuous
conveyors that moved them into and through the carbon dioxide gas.
2) Special requirements for gas chamber and auxiliary equipment:
The ability of anesthetizing equipment to perform with maximum efficiency is
dependent on its proper design and efficient mechanical operation. Pathways,
compartments, gas chambers, and all other equipment used must be designed to
accommodate properly the species of animals being anesthetized. They shall be
free from pain-producing restraining devices. Injury of animals must be
prevented by the elimination of sharp projections or exposed wheels or gears.
There shall be no unnecessary holes, spaces or openings where feet or legs of
animals may be injured. Impellers or other devices designed to mechanically
move or drive animals or otherwise keep them in motion or compartmentalized
shall be constructed of flexible or well padded rigid material. Power activated
gates designed for constant flow of animals to anesthetizing equipment shall be
so fabricated that they will not cause injury. All equipment involved in
anesthetizing animals shall be maintained in good repair.
3) Gas: Maintenance of a uniform carbon dioxide concentration and
distribution in the anesthesia chamber is a vital aspect of producing surgical
anesthesia. This may be assured by reasonably accurate instruments which sample
and analyze carbon dioxide gas concentration within the chamber throughout
anesthetizing operations. Gas concentration shall be maintained uniform so that
the degree of anesthesia in exposed animals will be constant. Carbon dioxide
gas supplied to anesthesia chambers will be from controlled reduction of solid
carbon dioxide or from a controlled liquid source. In either case the carbon
dioxide shall be supplied at a rate sufficient to anesthetize adequately and
uniformly the number of animals passing through the chamber. Sampling of gas
for analysis shall be made from a representative place or places within the
chamber and on a continuing basis. Gas concentrations and exposure time shall
be graphically recorded throughout each day's operation. Neither carbon dioxide
nor atmospheric air used in the anesthesia chambers shall contain noxious or
irritating gases. Each day before equipment is used for anesthetizing animals,
proper care shall be taken to mix adequately the gas and air within the chamber.
All gas producing and control equipment shall be maintained in good repair and
all indicators, instruments, and measuring devices must be available for
inspection by Division inspectors during anesthetizing operations and at other
times. An exhaust system must be provided so that, in case of equipment
failure, non-uniform carbon dioxide concentrations in the gas tunnel or
contamination of the ambient air of the establishment will be prevented.