92 Ill. Adm. Code 1535.365
Automatic Gates
Section 1535
Section 1535.365 Automatic
Gates
a) In general, controls for automatic gates shall conform to
current signal specifications of AREMA. Appropriate refinements in track
circuit controls such as "speed control," "time-out"
sections, presence detectors, motion detectors, and constant warning time
devices to prevent unnecessary delays to highway traffic shall be provided
consistent with the importance of the highway and the character and volume of
rail traffic.
b) Bell, when used, shall sound a warning from the time the
signal lights start to operate at least until the gate arm has descended to
within 10° of the horizontal position.
c) In case there is a failure of the automatic gates, the
railroad company will take action, as soon as it can be done, to give warning
to highway traffic until the gates are put in operable condition.
d) For interconnection of automatic flashing light signals and
gates with nearby traffic control signals procedures outlined in Section
1535.350(c) are to be followed.