92 Ill. Adm. Code 435.APPENDIX D
D Fire Extinguisher through Fuel System
Section 435.APPENDIX D Fire Extinguisher through Fuel
System
a) FIRE EXTINGUISHER
AGENCY NOTE: A fire extinguisher
is required to be carried on each MFSAB transporting students. The
manufacturer may elect to install the fire extinguisher at the time the MFSAB
is manufactured; however, a fire extinguisher can also be installed by the
owner after the MFSAB is purchased.
Pressurized dry-chemical gauge
type approved by Underwriters' Laboratories, Inc., with a rating of not less than
10 B.C., mounted in bracket and readily accessible. Sealed with a type of seal
that will not interfere with operation. If stored in locked compartment,
compartment must be labeled. Halon fire extinguishers (10 B.C.) are approved.
b) FIRST AID KIT
AGENCY NOTE: A first aid kit is
required to be carried on each MFSAB transporting students. The manufacturer
may elect to install the first aid kit at the time the MFSAB is manufactured;
however, a first aid kit can also be installed by the owner after the MFSAB is
purchased.
Kit shall be readily identifiable,
removable, and mounted in a readily accessible place in driver's compartment −
either in full view or in secured compartment (see LOCKED COMPARTMENT). If not
carried in compartment, the case shall be dust tight and substantially
constructed of durable material. The contents shall include, but not be
limited to, the following:
Unit Type
(Minimum Contents)
4" bandage compress − 2
packages
2" bandage compress − 2
packages
1" bandage or adhesive compress
− 1 package
40" triangle bandage with two
safety pins − 1
Splint, wire or wood − 1
A tourniquet or any type of
ointment, antiseptic or other medicine shall not be included.
AGENCY NOTE: OSHA
approved blood-borne pathogen kits are permitted.
c) FLOOR AND FLOOR COVERING
All portions of the floor that
come in contact with passengers' or driver's footwear shall be covered with a
waterproof material. This floor covering shall not crack when subjected to
sudden temperature change and shall be bonded securely to the floor with a
waterproof substance. All seams and openings shall be filled with a waterproof
sealer.
The floor covering in the aisles
and entrance area shall be of non-skid, wear-resistant type material commonly
used in commercial passenger transportation vehicles.
d) FRAME AND BODY
Body mounts shall be attached and
sealed to the chassis cowl so as to prevent the entry of water, dust or fumes
through the joint between the chassis cowl and the body.
Frame shall extend to rear of body
cross-member.
Frame extension is permitted when
alterations are behind rear hanger or rear springs and not for the purpose of
extending wheel base.
e) FUEL SYSTEM
The fuel system shall conform to
all applicable provisions of 49 CFR 571.301.
Entire fuel system, except
extensions for driver control of air or fuel, must be outside passenger and
driver compartment.
Fuel tank must have a minimum
capacity of 24 gallons, mounted, filled, and vented entirely outside body.