92 Ill. Adm. Code 441.APPENDIX A
A Air Cleaner through Barrier, Guard
Section 441.APPENDIX A Air
Cleaner through Barrier, Guard
a)
AIR CLEANER
PROCEDURE/SPECIFICATIONS:
Any type is acceptable.
REJECT VEHICLE IF:
Air cleaner is not properly
attached or is missing.
b)
AISLE
PROCEDURES/SPECIFICATIONS:
Unobstructed minimum clearance
leading from service door to emergency door (or back of bus) must be at least
12 inches (305 mm) wide. For buses manufactured in July 1987 or later, aisle
width at two inches below top of seat back must be 15 inches (380mm). Floor
to ceiling height must be a minimum of 68.9 inches (1.75m) at any location
within the aisle.
An aisle may be adjacent to
any side emergency door. For buses manufactured on or after September 1, 1994,
the following must be met:
1)
An unobstructed aisle
measuring at least 11.7 inches (30 cm) must be maintained at all times,
except with a flip-up seat is in the down position.
2)
No portion of the door latch
mechanism can be obstructed by a seat.
3)
The 11.7 inches (30 cm) aisle
is measured from the door opening to the seat back in front. (49 CFR
571.217)
AGENCY NOTE:
Flip-up seats are allowed.
See SEATS, PASSENGER for standards.
REJECT VEHICLE IF:
Aisle does not meet minimum standards.
c)
ALTERNATOR
(GENERATOR)
PROCEDURES/SPECIFICATIONS:
The generator, or alternator
with rectifier, shall have a minimum capacity rating of 60 amperes and shall
be capable of meeting all electrical requirements.
REJECT
VEHICLE IF:
Alternator does not meet
minimum standards or is not functioning.
d)
AXLES
PROCEDURES/SPECIFICATIONS:
Must meet
federal chassis requirements as indicated on federal certification label.
(49 CFR 568)
REJECT VEHICLE IF:
Axles show visible signs of
apparent damage, leaking fluids or are not firmly attached.
e)
BARRIER,
GUARD
PROCEDURES/SPECIFICATIONS:
A guard barrier, constructed
and thickly padded so as to provide head, knee and leg protection, shall be
installed in front of each forward facing passenger seat that does not
directly face the rear surface of another passenger seat. The barrier must
measure the same height as the passenger seat back directly behind that
barrier. (49 CFR 571.222).
In a bus manufactured in
January 1988 or later, guard barriers must measure the same height required
of the seat back directly behind that barrier.
Exception: In a bus
manufactured from July 1, 1987, to December 31, 1987, the barrier may measure
less than the seat back behind the barrier.
Exception: In a bus with
chassis (incomplete vehicle) manufactured in March 1977 or earlier, the
barrier may consist of a floor-to-ceiling vertical stanchion, padded to
within three inches of ceiling and floor, and a stanchion-to-wall, fully
padded, horizontal guard rail. However, if located adjacent to stepwell,
this type barrier shall include a stepwell guard panel that extends from the
stanchion to the wall and from the guard rail to within two inches of the
floor.
Exception: All buses
manufactured prior to September 1974 are exempt from padding on stanchions
and guard rails.
Exception: See 92 Ill. Adm.
Code 445.APPENDIX A (Inspection Procedures for Special Education School
Buses) for possible exception.
REJECT VEHICLE IF:
Barrier is not solidly
attached. Padding or covering shows wear and tear. Barrier does not meet
requirements.