92 Ill. Adm. Code 449.60
Pipe and Hose Installation
Section 449
Section 449.60 Pipe and Hose
Installation
In addition to the requirements
established by Section 449.30, pipes and hoses installed on school buses for
operation of an alternate fuel system shall comply with the following:
a) No fuel supply line shall pass through the driver or
passenger's compartment.
b) The pressure relief device shall be fabricated so that in the
event of stress, the pipe or adaptor will break away without impairing the
function of the relief valve.
c) If installed, the adaptor connecting the piping system to the
pressure relief device shall neither touch nor restrict any movable part of the
pressure relief valve.
d) The relief valve discharge piping system (piping system) must
not be reduced at any point from the relief valve to the point of release into
the atmosphere.
e) The piping system shall be routed to minimize sharp elbows or
bends. Installation of any commercially available piping installed to meet the
manufacturer's specifications is acceptable. Any fittings that restrict the
flow of discharge are prohibited. From the pressure relief device adaptor to
the atmosphere, the minimum inside diameter of the piping must measure at least
3/4 of an inch.
f) The piping system shall neither block nor hamper the operation
of any window or door. The piping system shall preserve widths of passageways,
aisles and emergency exits.
g) Every portion of the piping system shall be gas tight (except
the outlet) and shall be able to withstand forces from the discharge when the
relief valve is in full open position. If for any reason the discharge outlet
becomes blocked, the piping system must be capable of holding the full system
pressure.
h) To facilitate the removal of accumulated water, a drain cock
shall be installed at the lowest point of the piping system. The drain must be
capable of being held open manually and close automatically to prevent
expelling LPG if discharged through the relief valve. A weep hole, or other
opening that may result in discharged LPG flaming beneath the bus is
prohibited.
i) The portion of the piping system that leads upward to the
atmosphere shall be installed either inside the passenger compartment, on the
outside of the bus, or in the body wall between the inner and outer
"skins" of the bus body.
1) Piping on the outside of the body shall be shielded below the
window line to prevent "grabbing hold" or "hitching to."
However, discharge piping that is located between the windshield and the vent
window at the left front corner of the body need not be shielded.
2) Any portion of the piping system that is installed either
inside the passenger compartment or inside the body wall shall consist of one
piece originating below the bus floor and exiting outside the bus roof. Every
hole where piping passes through the floor or roof shall be sealed.
j) The piping system must terminate above the eave lines of the
bus body.
k) The outlet of the piping system shall be located at least 36
inches from the air inlet or outlet of a ventilator or similar device installed
on or near the roof. A "similar device" includes the fresh air
intake of a heating, ventilating or air conditioning system. It does not
include a side window that opens near the roof.
l) A rain cap is required where the piping system exits into the
atmosphere to minimize water or dirt from entering into either the relief valve
or its discharge piping. Installation of any commercially available rain cap
installed to meet the manufacturer's specifications is acceptable. The cap
shall remain in place except when the relief valve operates. The cap shall be
installed to minimize the entrance of water or dirt while the vehicle is in
motion.
m) The discharge piping system on a special education school bus
shall conform to all provisions of this Part.