92 Ill. Adm. Code 456.80
Violation Criteria for Alternate Fuel School Buses
Section 456
Section 456.80 Violation
Criteria for Alternate Fuel School Buses
Alternate fuel school buses are
subject to the inspection requirements of Section 456.60 and the following:
a) Pipe Hose and Fittings:
1) OUT-OF-SERVICE – incorrect pipe size; fuel supply line that
passes through driver or passenger compartment; reduced piping system;
incorrect piping material; piping system blocks or hampers window or door;
piping system is not located at least 36 inches from air inlet or outlet;
missing drain cock; missing rain cap; piping system is not one piece
originating below the bus floor and exiting outside the bus roof; holes where
pipe exits or enters are not sealed; piping system does not terminate above the
eave line or does extend above the roof of the bus.
2) 3-DAY – any parts remain from alternate fuel system after
conversion to gasoline or diesel; no longer used but not made inoperable.
3) WARNING – Shielding is not present on piping outside the body
below the window line.
b) Container and Container Appurtenances:
OUT-OF-SERVICE – Incorrect
location; valves, appurtenances and connections are not mounted in enclosed
compartment.
c) Identification Decal:
WARNING – missing.