410 IAC 5-10.1-12
410 IAC 5-10.1-12 Sealed sources used in downhole operations
Cite as Ind. Admin. Code tit. 410, r. 5-10.1-12
Sec. 12. Design, Performance, and Certification Criteria for Sealed Sources Used in Downhole Operations.
(a) Each sealed source, except those containing radioactive material in gaseous form, used in downhole operations and manufactured one
year after the effective date of 410 IAC 5 shall be certified by the manufacturer or other testing organization acceptable to the board
to meet the following minimum criteria:
(1) Be of doubly encapsulated construction;
(2) Contain radioactive material whose chemical and physical forms are as insoluble and nondispersible as practical; and
(3) Has been individually pressure tested to at least 24,656 pounds per square inch absolute (170 MN/m2) without
failure.
(b) For sealed sources, except those containing radioactive material in gaseous form, acquired one year after the effective date of 410 IAC 5, in the absence of a certificate from a transferor certifying that an individual sealed source meets the requirements of 410 IAC 5-10.1-12(a), the sealed source shall not be put into use until such determinations and testing have been performed.
(c) Each sealed source, except those containing radioactive material in gaseous form, used in downhole operations two years after the
effective date of 410 IAC 5 shall be certified by the manufacturer, or other testing organization acceptable to the board, as meeting the
sealed source performance requirements for oil well-logging as contained in the American National Standard N542, "Sealed Radioactive Sources,
Classification" in effect on the effective date of 410 IAC 5.
(d) Certification documents shall be maintained for inspection by the board for a period of 2 years after source disposal. If the source is
abandoned downhole, the certification documents shall be maintained until the board authorizes disposition.