410 IAC 5-1-12

410 IAC 5-1-12 Tests for special form licensed material

Last amended: 2025Year: 2027Length: 160 wordsOfficial source

Cite as Ind. Admin. Code tit. 410, r. 5-1-12

Sec. 12. APPENDIX B TESTS FOR SPECIAL FORM LICENSED MATERIAL (1) Free Drop–A free drop through a distance of 30 feet (9.14 meters) onto a flat essentially unyielding horizontal surface, striking the surface in such a position as to suffer maximum damage. (2) Percussion–Impact of the flat circular end of a 1 inch (2.54 centimeters) diameter steel rod weighing 3 pounds (1.36 kilograms), dropped through a distance of 40 inches (1.02 meters). The capsule or material shall be placed on a sheet of lead, of hardness number 3.5 to 4.5 on the Vickers scale, and not more than 1 inch (2.54 centimeters) thick, supported by a smooth essentially unyielding surface. (3) Heating–Heating in air to a temperature of 1475° F (801.67° C) and remaining at that temperature for a period of 10 minutes. (4) Immersion–Immersion for 24 hours in water at room temperature. The water shall be at pH 6-pH 8, with a maximum conductivity of 10 micromhos per centimeter.