410 IAC 5-5-5
410 IAC 5-5-5 Locking of sources for gamma radiography
Cite as Ind. Admin. Code tit. 410, r. 5-5-5
Sec. 5. (a) Each source of radiation shall be provided with a lock or lockable outer container designed to prevent unauthorized or accidental
production of radiation or removal or exposure of a sealed source and shall be kept locked at all times except when under the direct surveillance
of a radiographer or radiographer's assistant, or as may be otherwise authorized pursuant to 410 IAC 5-5-15. Each storage container
and source changer likewise shall be provided with a lock and shall be kept locked when containing sealed sources except when the container is under
the direct surveillance of a radiographer or radiographer's assistant.
(b) Radiographic exposure devices, source changers, and storage containers, prior to being moved from one location to another and also
prior to being secured at a given location, shall be locked and surveyed to assure that the sealed source is in the shielded position.