410 IAC 6-2.1-32

410 IAC 6-2.1-32 Recirculation

Last amended: 2025Year: 2027Length: 177 wordsOfficial source

Cite as Ind. Admin. Code tit. 410, r. 6-2.1-32

Sec. 32. (a) The recirculation system shall be maintained in accordance with the following: (1) The turnover rate for spas shall be once every half hour. (2) For pools, except spas, built before September 13, 1989, the turnover rate shall be the lesser of the following times: (A) Eight (8) hours. (B) The maximum pool capacity in gallons, divided by the maximum bather load, divided again by one hundred eight (108) gallons per hour per bather. (b) In all other pools built on or after September 13, 1989, the turnover rate shall be as follows: POOL TYPE TURNOVER RATE Wading pools 1 hour Wave pools 2 hours Zero depth pools 2 hours Pools with wading areas 2 hours Competition pools 6 hours Diving pools 12 hours All other pools 6 hours (c) A suitable means shall be provided to measure the flow of water through the pool water recirculation system. (d) Footbaths are prohibited. (e) All public and semi-public pools and spas must comply with the Virginia Graeme Baker Pool and Spa Safety Act, 15 U.S.C. 8001-8008.
410 IAC 6-2.1-32: 410 IAC 6-2.1-32 Recirculation | Justis AI