105 IAC 16.5-1-18
105 IAC 16.5-1-18 Fiber optic locator post
Cite as Ind. Admin. Code tit. 105, r. 16.5-1-18
Sec. 18. (a) Fiber optic locator post must be installed to comply with the permit plans and specifications.
(b) The fiber optic locator post must be made of a nonconductive, high-density polymer, and integrally white in color with an orange cap
with black graphic and lettering on two sides. The colors must be stabilized against ultraviolet light so they will not fade under continuous exposure
to direct sunlight. The marker must retain dimensional stability in temperatures ranging between negative forty (40) degrees Fahrenheit and one
hundred seventy-five (175) degrees Fahrenheit. Each post must be able to withstand a single vehicle impact at forty-five (45) miles per hour and
return to within ten (10) degrees of vertical within sixty (60) seconds.
(c) A locator post must be installed at each fiber optic splice location. At splice points, the posts must be connected to the fiber splice cases
and the armored cable with a #12 tracer wire in innerduct as shown on the plans.
(d) Locator posts must be installed at the same time, or immediately after the installation of the underground conduits and vaults for
identification of underground infrastructure.