Sec. 35. Change the text of SECTION R322.1.8 to read as follows:
Building materials and installation methods for flooring and interior and exterior walls and wall coverings below the elevation required
in Section R322.2 (flood hazard areas including A Zones) or Section R322.3 (coastal high-hazard areas including V Zones) shall comply with the
following:
1. All wood, including floor sheathing, shall be pressure-preservative-treated in accordance with AWPA U1 for the species, product,
preservative, and end use or be the decay-resistant heartwood of redwood, black locust, or cedars. Preservatives shall be listed in Section 4 of AWPA
U1.
2. Materials and installation methods used for flooring and interior and exterior walls and wall coverings shall conform to the provisions
of FEMA Technical Bulletin 2 / August 2008.