675 IAC 14-4.4-35

675 IAC 14-4.4-35 Section R322.1.8; flood resistant materials

Last amended: 2025Year: 2027Length: 126 wordsOfficial source

Cite as Ind. Admin. Code tit. 675, r. 14-4.4-35

Sec. 35. Change the text of SECTION R322.1.8 to read as follows: Building materials and installation methods for flooring and interior and exterior walls and wall coverings below the elevation required in Section R322.2 (flood hazard areas including A Zones) or Section R322.3 (coastal high-hazard areas including V Zones) shall comply with the following: 1. All wood, including floor sheathing, shall be pressure-preservative-treated in accordance with AWPA U1 for the species, product, preservative, and end use or be the decay-resistant heartwood of redwood, black locust, or cedars. Preservatives shall be listed in Section 4 of AWPA U1. 2. Materials and installation methods used for flooring and interior and exterior walls and wall coverings shall conform to the provisions of FEMA Technical Bulletin 2 / August 2008.