675 IAC 20-2-18
675 IAC 20-2-18 Filters
Cite as Ind. Admin. Code tit. 675, r. 20-2-18
Sec. 18. (a) Filters shall be designed and constructed so that after cleaning per manufacturer's instructions the system can provide the water
clarity such that a six (6) inch black disc, placed upon a white background, is clearly visible at the deepest point of the pool when viewed from the
edge of the pool.
(b) Filters shall be designed so that filtration surfaces can be inspected and serviced.
(c) On pressure-type filters, a means shall be provided to permit the release of air which enters the filter tank. Any filter incorporating an
automatic internal air release as its principal means of air release must have lids which provide a slow and safe release of pressure as a part of its
design. Any separation tank used in conjunction with any filter tank must have a manual means of air release or lid which provides a slow and safe
release of pressure as they are opened as a part of its design.
(d) Pressure filters and separation tanks shall have operation and maintenance instructions permanently installed on the filter or separation
tank and shall include a precautionary statement warning not to start up the system after maintenance without first opening the air release and proper
reassembly of the filter and separation tank. The statement must be visible and noticeable within the area of the air release.
(e) Piping furnished with the filter shall be of suitable material capable of withstanding one and one-half (1 1/2) times the working
pressure.
(f) Filter components which require servicing shall be accessible for inspection and repair when installed according to the manufacturer's
instructions.
(g) The rate of filtration shall not exceed three (3) gallons per minute per square foot of filter surface unless the filtration system is
specifically listed and labeled for use above said rate.