675 IAC 20-2-3
675 IAC 20-2-3 Structural design
Cite as Ind. Admin. Code tit. 675, r. 20-2-3
Sec. 3. (a) All pools shall be designed and constructed to withstand all anticipated loading for both empty and full conditions. A hydrostatic
relief valve shall be provided for all in-ground pools. The design professional as described in 675 IAC 12, the general administrative
rules, shall be responsible for the structural stability as described above.
(b) Sand or earth shall not be permitted as an interior finish in a public swimming pool.
(c) In all pools not completely enclosed in a heated building, the pool shell and appurtenances, piping, filter system, pump, motor, and other
components shall be so designed and constructed to facilitate protection from damage due to freezing.
(d) The surfaces within a swimming pool intended to provide footing for bathers shall be designed to provide a slip-resisting surface. The
roughness or irregularity of the surfaces shall not provide an abrasion hazard to the feet during normal use.
(e) The color, pattern, or finish of the pool interior shall not obscure the existence or presence of objects or surfaces within the pool. The
floor of all pools shall be white, light colored, or light colored patterns in order to facilitate the identification of any objects within the pool. For
purposes of this section, "light colored" means having a light reflectance value (LRV) of sixty percent (60%) or more.