675 IAC 27-1-7

675 IAC 27-1-7 Maneuvering clearances at doorways without doors

Last amended: 2023Year: 2027Length: 120 wordsOfficial source

Cite as Ind. Admin. Code tit. 675, r. 27-1-7

Sec. 7. (a) Doorways without doors that are less than thirty-six (36) inches (nine hundred fourteen (914) millimeters) wide shall have maneuvering clearances complying with TABLE V7.1 as follows: TABLE V7.1 MANEUVERING CLEARANCES FOR DOORWAYS WITHOUT DOORS APPROACH DIRECTION MINIMUM CLEARANCES PERPENDICULAR TO DOORWAY1 48 inches (1,219 mm) From side 42 inches (1,067 mm) 1Maneuvering space shall include full width of doorway. (b) Where the plane of the doorway is recessed more than eight (8) inches (twenty and three-tenths (20.3) centimeters) from the plane of the wall, clearances for front approach shall be provided. (c) Floor or ground surface within the maneuvering clearances shall have a slope not greater than 1:48 and shall comply with section 13 of this rule.
675 IAC 27-1-7: 675 IAC 27-1-7 Maneuvering clearances at doorways without doors | Justis AI