312 IAC 13-5-1
312 IAC 13-5-1 Materials and installation
Cite as Ind. Admin. Code tit. 312, r. 13-5-1
Sec. 1. (a) This section governs grouting materials and the installation of grouting materials for new wells.
(b) Grouting materials shall consist of:
(1) neat cement with no more than five percent (5%) by weight of bentonite additive;
(2) bentonite slurry (which can include polymers designed to retard swelling);
(3) pelletized, granular, medium grade, or coarse grade crushed bentonite; or
(4) other materials approved by the commission.
(c) This section applies if neat cement or a bentonite slurry is used for grouting. The cement or slurry shall be pumped into place from the
bottom of the annular space upward in a continuous operation with a grout pipe or the well casing using the positive displacement method.
(d) Grouting material, other than neat cement or bentonite slurry, shall be introduced in a manner to prevent bridging of the annulus between
the outside of the well casing and the borehole.
(e) A borehole annulus shall be grouted upon the earlier of the following:
(1) Within twenty-four (24) hours after the installation of the well casing.
(2) Before drilling equipment is removed from the site.
(f) This section does not apply to a public water supply well. The installation of a public water supply well is governed by 327 IAC
8-3.4.