327 IAC 20-5-3
327 IAC 20-5-3 Design requirements for liners
Cite as Ind. Admin. Code tit. 327, r. 20-5-3
Sec. 3. (a) The soil or foundation of an earthen SMSS must have a maximum specific discharge of one-sixteenth (1/16)
in3/in2/day, 1.8x10-6cm3/cm2/sec. This requirement may be satisfied by soil
testing that shows a minimum of three (3) feet of in situ soils that:
(1) meet the maximum specific discharge criteria;
(2) are over-excavated a minimum of six (6) inches; and
(3) are recompacted to break up the existing macropore structure.
(b) If there is not at least three (3) feet of in situ soils that meet the maximum specific discharge criteria in subsection (a), a liner must be
used. Except for clay liners described in subsection (c), liners used in a SMSS must meet the following design standards as applicable:
(1) Indiana NRCS Conservation Practice Standard Code 520: Pond Sealing or Lining, Compacted Soil Treatment, October
2016*.
(2) Indiana NRCS Conservation Practice Standard Code 522: Pond Sealing or Lining – Concrete, October
2016*.
(c) Clay liners must be a minimum of one (1) foot thick and have a maximum specific discharge of one-sixteenth (1/16)
in3/in2/day, 1.8x10-6cm3/cm2/sec.