327 IAC 6.1-7-7

327 IAC 6.1-7-7 Domestic wastewater treatment reliability criteria

Last amended: 2026Year: 2027Length: 140 wordsOfficial source

Cite as Ind. Admin. Code tit. 327, r. 6.1-7-7

Sec. 7. The supervisor of a domestic sewage treatment works requiring disinfection equipment dependent upon electricity for operation shall submit documentation for approval by the commissioner demonstrating the ability to: (1) provide an alternative power source sufficient to operate pathogen reduction equipment to a degree that pathogen limitations detailed in section 2 or 3 of this rule are achieved; (2) upon the reduction, loss, or failure of power to the disinfection equipment, cease land application of domestic wastewater and cease discharge to a domestic wastewater storage structure used for land application of domestic wastewater for a period of seventy-two (72) hours; or (3) provide an effective alternate method of disinfection, sufficient to a degree that pathogen limitations detailed in section 2 or 3 of this rule are achieved, approved by the commissioner, that does not require electricity for proper operation.