LAC 43:XIII.1503

LAC 43:XIII.1503. General [49 CFR 192.273]

Last amended: 2004Year: 2026Length: 80 wordsOfficial source

Cite as La. Admin. Code tit. 43, pt. XIII, § 1503

A. The pipeline must be designed and installed so that each joint will sustain the longitudinal pullout or thrust forces caused by contraction or expansion of the piping or by anticipated external or internal loading. [49 CFR 192.273(a)] B. Each joint must be made in accordance with written procedures that have been proved by test or experience to produce strong gastight joints. [49 CFR 192.273(b)] C. Each joint must be inspected to insure compliance with this Chapter. [49 CFR 192.273(c)]