LAC 43:XIII.2109. External Corrosion Control: Buried or Submerged Pipelines Installed before August 1, 1971 [49 CFR 192.457]
Cite as La. Admin. Code tit. 43, pt. XIII, § 2109
A. Except for buried piping at compressor, regulator, and measuring stations, each buried or submerged transmission line installed before August 1, 1971, that has an effective external coating must be cathodically protected along the entire area that is effectively coated, in accordance with this Chapter. For the purposes of this Chapter, a pipeline does not have an effective external coating if its cathodic protection current requirements are substantially the same as if it were bare. The operator shall make tests to determine the cathodic protection current requirements. [49 CFR 192.457(a)]
B. Except for cast iron or ductile iron, each of the following buried or submerged pipelines installed before August 1, 1971, must be cathodically protected in accordance with this Chapter in areas in which active corrosion is found: [49 CFR 192.457(b)]
1. bare or ineffectively coated transmission lines; [49 CFR 192.457(b)(1)]
2. bare or coated pipes at compressor, regulator, and measuring stations; [49 CFR 192.457(b)(2)]
3. bare or coated distribution lines. [49 CFR 192.457(b)(3)]