LAC 43:XIII.2141
LAC 43:XIII.2141. Remedial Measures: Cast Iron and Ductile Iron Pipelines [49 CFR 192.489]
Cite as La. Admin. Code tit. 43, pt. XIII, § 2141
A. General Graphitization. Each segment of cast iron or ductile iron pipe on which general graphitization is found to a degree where a fracture or any leakage might result, must be replaced. [49 CFR 192.489(a)]
B. Localized Graphitization. Each segment of cast iron or ductile iron pipe on which localized graphitization is found to a degree where any leakage might result, must be replaced or repaired, or sealed by internal sealing methods adequate to prevent or arrest any leakage. [49 CFR 192.489(b)]