LAC 43:XIII.2919

LAC 43:XIII.2919. Transmission Lines: Testing of Repairs [49 CFR 192.719]

Last amended: 2004Year: 2026Length: 88 wordsOfficial source

Cite as La. Admin. Code tit. 43, pt. XIII, § 2919

A. Testing of Replacement Pipe. If a segment of transmission line is repaired by cutting out the damaged portion of the pipe as a cylinder, the replacement pipe must be tested to the pressure required for a new line installed in the same location. This test may be made on the pipe before it is installed. [49 CFR 192.719(a)] B. Testing of Repairs Made by Welding. Each repair made by welding in accordance with §§2913, 2915, and 2917 must be examined in accordance with §1321. [49 CFR 192.719(b)]
LAC 43:XIII.2919: LAC 43:XIII.2919. Transmission Lines: Testing of Repairs [49 CFR 192.719] | Justis AI