LAC 43:XIII.709
LAC 43:XIII.709. Plastic Pipe [49 CFR 192.59]
Cite as La. Admin. Code tit. 43, pt. XIII, § 709
A. New plastic pipe is qualified for use under this Subpart if: [49 CFR 192.59(a)]
1. it is manufactured in accordance with a listed specification; [49 CFR 192.59(a)(1)]
2. it is resistant to chemicals with which contact may be anticipated; and [49 CFR 192.59(a)(2)]
3. it is free of visible defects. [49 CFR 192.59(a)(3)]
B. Used plastic pipe is qualified for use under this Subpart if: [49 CFR 192.59(b)]
1. it was manufactured in accordance with a listed specification; [49 CFR 192.59(b)(1)]
2. it is resistant to chemicals with which contact may be anticipated; [49 CFR 192.59(b)(2)]
3. it has been used only in natural gas service; [49 CFR 192.59(b)(3)]
4. its dimensions are still within the tolerances of the specification to which it was manufactured; and [49 CFR 192.59(b)(4)]
5. it is free of visible defects. [49 CFR 192.59(b)(5)]
C. For the purpose of Paragraphs A.1 and B.1 of this Section, where pipe of a diameter included in a listed specification is impractical to use, pipe of a diameter between the sizes included in a listed specification may be used if it: [49 CFR 192.59(c)]
1. meets the strength and design criteria required of pipe included in that listed specification; and [49 CFR 192.59(c)(1)]
2. is manufactured from plastic compounds which meet the criteria for material required of pipe included in that listed specification. [49 CFR 192.59(c)(2)]
D. Rework and/or regrind material is not allowed in plastic pipe produced after March 6, 2015 used under this part. [49 CFR 192.59(d)]