LAC 46:XL.313

LAC 46:XL.313. Exterior System

Last amended: 2025Year: 2026Length: 222 wordsOfficial source

Cite as La. Admin. Code tit. 46, pt. XL, ยง 313

A. The home inspector shall inspect: 1. wall cladding, flashings and trim; 2. all doors, including garage doors and storm doors; 3. all readily accessible windows; 4. decks, balconies, stoops, steps, porches, and applicable railings; 5. eaves, soffits, and fascias where visible from the ground level; and 6. vegetation, grading, drainage, driveways, patios, walkways, and retaining walls with respect to their effect on the condition of the building. B. The home inspector shall: 1. describe wall cladding materials; 2. operate all entryway doors; 3. operate garage doors and test the electronic safety beam reverse feature by interrupting the electronic beam (if present); and 4. report whether or not the garage door operator is equipped with a pressure sensitive safety reverse feature and whether that feature was tested. C. The home inspector is not required to inspect: 1. shutters, awnings, and similar seasonal accessories; 2. fences; 3. presence of safety glazing in doors and windows; 4. garage door operator remote control transmitters, unless the device is the only control device; 5. geological conditions; 6. soil conditions; 7. recreational facilities; 8. detached buildings or structures other than garages and carports; 9. the presence or condition of buried fuel storage tanks; 10. sea walls, break walls or docks; 11. erosion control and earth stabilization measures; or 12. garage door operator pressure sensitive reverse failure devices.