LAC 7:XXV.159

LAC 7:XXV.159. Containment Pads

Last amended: 2013Year: 2026Length: 155 wordsOfficial source

Cite as La. Admin. Code tit. 7, pt. XXV, § 159

A. Existing containment pads shall: 1. intercept leaks and spills; and 2. have enough surface area to extend under containers on it; and 3. accommodate at least the portion of the vehicle where the hose or device couples to it, for transport vehicles delivering pesticide; and 4. allow for removal/recovery of spilled, leaked or discharged material and rainfall; and 5. have no automatic pumps without overflow cutoffs. B. New containment pads to be designed and constructed shall: 1. intercept leaks and spills; and 2. have enough surface area to extend under containers on it; and 3. accommodate at least the portion of the vehicle where the hose or device couples to it, for transport vehicles delivering pesticide; and 4. allow for removal/recovery of spilled, leaked or discharged material and rainfall; and 5. have no automatic pumps without overflow cutoffs; and 6. have their surface sloped toward an area where liquids can be collected for removal.
LAC 7:XXV.159: LAC 7:XXV.159. Containment Pads | Justis AI