LAC 33:V.30254

LAC 33:V.30254. Above Ground Components [49 CFR 195.254]

Last amended: 2003Year: 2026Length: 100 wordsOfficial source

Cite as La. Admin. Code tit. 33, pt. V, § 30254

A. Any component may be installed above ground in the following situations, if the other applicable requirements of this Subpart are complied with: [49 CFR 195.254(a)] 1. overhead crossing of highways, railroads, or body of water; [49 CFR 195.254(a)(1)] 2. spans over ditches and gullies; [49 CFR 195.254(a)(2)] 3. scraper traps or block valves; [49 CFR 195.254(a)(3)] 4. area under the direct control of the operator; [49 CFR 195.254(a)(4)] 5. in any area inaccessible to the public. [49 CFR 195.254(a)(5)] B. Each component covered by §30254 must be protected from the forces exerted by the anticipated loads. [49 CFR 195.254(b)]