LAC 33:V.30404
LAC 33:V.30404. Maps and Records [49 CFR 195.404]
Cite as La. Admin. Code tit. 33, pt. V, § 30404
A. Each operator shall maintain current maps and records of its pipeline systems that include at least the following information: [49 CFR 195.404(a)]
1. location and identification of the following pipeline facilities: [49 CFR 195.404(a)(1)]
a. breakout tanks; [49 CFR 195.404(a)(1)(i)]
b. pump stations; [49 CFR 195.404(a)(1)(ii)]
c. scraper and sphere facilities; [49 CFR 195.404(a)(1)(iii)]
d. pipeline valves; [49 CFR 195.404(a)(1)(iv)]
e. facilities to which §30402.C.9 applies; [49 CFR 195.404(a)(1)(v)]
f. rights-of-way; and [49 CFR 195.404(a)(1)(vi)]
g. safety devices to which §30428 applies; [49 CFR 195.404(a)(1)(vii)]
2. all crossings of public roads, railroads, rivers, buried utilities, and foreign pipelines; [49 CFR 195.404(a)(2)]
3. the maximum operating pressure of each pipeline; [49 CFR 195.404(a)(3)]
4. the diameter, grade, type, and nominal wall thickness of all pipe. [49 CFR 195.404(a)(4)]
B. Each operator shall maintain for at least three years daily operating records that indicate: [49 CFR 195.404(b)]
1. the discharge pressure at each pump station; and [49 CFR 195.404(b)(1)]
2. any emergency or abnormal operation to which the procedures under §30402 apply. [49 CFR 195.404(b)(2)]
C. Each operator shall maintain the following records for the periods specified: [49 CFR 195.404(c)]
1. the date, location, and description of each repair made to pipe shall be maintained for the useful life of the pipe; [49 CFR 195.404(c)(1)]
2. the date, location, and description of each repair made to parts of the pipeline system other than pipe shall be maintained for at least one year; [49 CFR 195.404(c)(2)]
3. a record of each inspection and test required by this Chapter shall be maintained for at least two years or until the next inspection or test is performed, whichever is longer. [49 CFR 195.404(c)(3)]